Download Multi-Services Transport Application
Transcript
user_guide.book Page 317 Tuesday, May 25, 2004 9:28 AM Telecom Concepts 11 4 The Head-End node finishes by performing a Switch operation if necessary. Measuring Protection Switch Time The Protection Switch Time of a transmission system should be equal to or less than 50 milliseconds. The switching process is dominated by the protocol processing time at each node on the Protection Circuit. The ITU-T standards specifies Protection Switch Time and the ‘detection times’ for various SF and SD conditions. Protection switching can be initiated by the following events: 1 Signal Fail (SF): usually loss of signal, loss of framing, or a very high error ratio such as 10E-03 or greater. 2 Signal Degrade (SD): a persistent background error rate that exceeds a provisioned threshold in the range 10E-05 to 10E-09. Note that, at the Multiplex Section level, ITU-T G.806 (October 2000 draft) specifies the ‘detection time’ for these errors as 10E-09. To reliably measure protection switching time, you need to measure the service disruption time associated with a SF/SD condition that either minimizes the ‘detection time’ (create a LOS failure – typically detected in less than 100 ms), or eliminates the ‘detection time’ (generate control Parity Errors (B2 and B3) on the entity being protected). Dividing service disruption time into its component parts is necessary due to the wide variation in detection times for different SF/SD conditions. Detection Times These range from 100 microseconds for a LOS failure to 10,000 seconds for a Signal Degrade that has a provisioned threshold of 10E-09 error rate. Also, the nature of some faults can be very unpredictable. For example, when a fiber is damaged during construction work it may not break cleanly. Instead, the optical signal may fade over several tens of milliseconds or vary erratically before finally disappearing. So the ITU-T standards require that, once SF/SD is detected, a Protection Switch event must be completed in 50 milliseconds or less. This is a User Guide 317