Download User Manual - SharePoint
Transcript
GB for AUSTRALIA 6 GN 1/1 n° GRIGLIE AOS061GAG1 AOS061GBG2 AOS061GAD1 AOS061GBD2 FCZ061GAG1 FCZ061GBG2 FCZ061GAD1 FCZ061GBD2 MODEL AOS061GCG2 AOS061GCD2 FCZ061GCG2 FCZ061GCD2 CONVECTOR BOILER o x PHASES (No) BS/P connection Ø 6GN2/1 10 GN 1/1 (AOS061E) ox ox ox ox ox ox ox ox AOS101GAG1 AOS101GBG2 AOS101GAD1 AOS101GBD2 FCZ101GAG1 FCZ101GBG2 FCZ101GAD1 FCZ101GBD2 o o o o AOS101GCG2 AOS101GCD2 FCZ101GCG2 FCZ101GCD2 o x o o x o 1+N 1+N 1+N 1+N 1/2" M 1/2" M 1/2" M 1/2" M 10 GN 2/1 ox ox ox ox ox ox ox ox AOS102GAG1 AOS102GBG2 AOS102GAD1 AOS102GBD2 FCZ102GAG1 FCZ102GBG2 FCZ102GAD1 FCZ102GBD2 o o o o AOS102GCG2 AOS102GCD2 FCZ102GCG2 FCZ102GCD2 ° x ox ox ox ox ox ox ox ox 20 GN 1/1 AOS201GAG1 AOS201GBG2 AOS201GAD1 AOS201GBD2 FCZ201GAG1 FCZ201GBG2 FCZ201GAD1 FCZ201GBD2 o o o o AOS201GCG2 AOS201GCD2 FCZ201GCG2 FCZ201GCD2 20 GN 2/1 ox ox ox ox ox ox ox ox AOS202GAG1 o x AOS202GBG2 o x AOS202GAD1 o x AOS202GBD2 o x FCZ202GAG1 o x FCZ202GBG2 o x FCZ202GAD1 o x FCZ202GBD2 o x o o o o AOS202GCG2 o AOS202GCD2 o FCZ202GCG2 o FCZ202GCD2 o o x o o x o ° x o x o 1+N 1+N 1+N 1+N 13 1+N 1+N 1/2" M 1/2" M 1/2" M 1/2" M 25 1/2" M 1/2" M Natural Gas test point pressure - (KPa) 1.13 1.13 1.13 1.13 1.13 1.13 1.13 1.13 4,5°° 1.13 1.13 Propane Gas test point pressure (KPa) 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 4,6 2.75 2.75 Propane Gas consumption (MJ/h) ** 67.2 39.5 159 88 174.2 99 251.2 176 4,6 356.4 198 Natural Gas consumption (MJ/h) ** 67,2 39.5 137 72 174.2 99 219.2 144 4,6 373.4 215 Noise emission data: Noise emissions generated by the appliances described in this booklet do not exceed 70 dB (A). * Your appliance model is indicated in the box marked PNC on the Identification dataplate affixed to the bottom left hand side of the oven. ** Gas consumption was calculated in the following conditions: - Temperature 15°C; - Atmospheric pressure 1013.25 mbar; - Net calorific value : G30 (Hi=45.65 MJoule/kg) G31 LPG (Hi=46.34 MJoule/kg) G20 natural gas (Hi=34.02 MJoule/m3) G25 natural gas (Hi=29.25 MJoule/m3) LPG (Japan) (Hi=46.34 MJoule/kg) 13A natural gas (Japan) (Hi=34.02 MJoule/m3) 2. DESCRIPTION OF APPLIANCE This booklet describes a number of appliance models. For more detailed information about the model in your possession, refer to "Technical Data" table 1. for AUSTRALIA Propane Gas (Hi=95.8 MJ/m3) Natural Gas (Hi=37.8 MJ/m3) The appliance has the following features: • Digital temperature indicator. • Thermostatic probe for measuring the core temperature of products (core temperature probe). • Continuous monitoring of cooking parameters throughout the entire cooking cycle. • Periodic draining and automatic washing of the boiler to prevent the build-up of lime-scale (only available on certain models). • Boiler lime-scale level indicator (see corresponding paragraph) (only available on certain models). • Oven chamber automatic fast steam drain device for gratins. • Air-break anti-backup drain device to prevent backflows from the drainage system from entering the oven (only available on certain models). • Oven chamber lighting. • Double-action door opening safety mechanism designed to protect the user from scalding steam (only available on certain models). • Double-glazed oven door for reduced heat dispersion into the kitchen and low temperatures on the exterior of the oven. • Daily oven chamber cleaning cycle (CLEANING SYSTEM) (only available on certain models). • Self-diagnostics system indicating oven faults using error codes (see "Information and error codes "). ^ FUNCTIONAL LEVEL (C=Convect, Covection). For UK and COMMONWEALTH only: 5938 034 01 This appliance is designated as a forced draught burner, therefore the appliance is classed as COMCAT5 and only installers who held the relevant gas qualification are allowed to install/commission and service this product. WARNING: Failure to use a qualified/authorised installer WILL INVALIDATE THE WARRANTY conditions and may render the appliance inoperative. If any doubt please consult the manufacturer for further advice. Under no circumstances must this product be used unless installed and /or commissioned by a qualified engineer. 33