Specifications Input Rating Output Rating Voltage Class Model Number VFD-XXXV 007 Max. Applicable Motor Output (kW) 0.75 Max. Applicable Motor Output (hp) 1.0 1.9 Rated Output Capacity (kVA) Rated Output Current for 5.0 Constant Torque (A) Rated Output Current for 6.25 Variable Torque (A) Maximum Output Voltage (V) Output Frequency (Hz) Carrier Frequency (kHz) 6.4 Rated Input Current (A) Rated Voltage/Frequency Voltage Tolerance Frequency Tolerance Cooling Method Weight (kg) Input Rating Output Rating Voltage Class Model Number VFD-XXXV Max. Applicable Motor Output (kW) Max. Applicable Motor Output (hp) Rated Output Capacity (kVA) Rated Output Current for Constant Torque (A) Rated Output Current for Variable Torque (A) Maximum Output Voltage (V) Output Frequency (Hz) Carrier Frequency (kHz) Rated Input Current (A) 022 2.2 3.0 4.2 037 3.7 5.0 6.5 055 5.5 7.5 9.5 7.5 11 17 25 33 9.4 13 21 31 41 Control Characteristics h a Control System Start Torque Speed Control Range Speed Control Resolution Speed Response Ability Max. Output Frequency Output Frequency Accuracy Frequency Setting Resolution Torque Limit Torque Accuracy Accel/Decel Time V/f Curve Frequency Setting Signal Brake Torque Motor Protection 150 15 20 25 185 18.5 25 29 220 22 30 34 300 30 40 46 370 37 50 55 49 65 75 90 120 146 61 81 93 112 150 182 68 79 106 126 13 13 36 36 3-Phase Proportional to Input Voltage 0.00~600.00 Hz 9 15 9.9 15 21 25 33 52 63 6 3-phase 200-240V, 50/60Hz ± 10%(180~264 V) ± 5%(47~63 Hz) Fan Cooled 10 13 13 Natural 2.7 3.2 4.5 6.8 8 022 2.2 3.0 4.2 037 3.7 5.0 6.3 460V Class 055 075 110 150 185 5.5 7.5 11 15 18.5 7.5 10 15 20 25 9.9 14 18 24 29 220 300 370 450 550 750 22 30 37 45 55 75 30 40 50 60 75 100 34 46 56 69 80 100 3.0 4.2 6.0 8.5 13 18 24 32 38 45 60 73 91 3.8 5.3 7.5 10 16 22 30 40 47 56 75 91 113 138 188 007 0.75 1.0 2.3 015 1.5 2.0 3.2 15 4.0 5.8 7.4 9.9 Rated Voltage Voltage Tolerance Frequency Tolerance Cooling Method Weight (kg) 230V Class 075 110 7.5 11 10 15 13 19 015 1.5 2.0 2.7 3-phase Proportional to Input Voltage 0.00~600.00 Hz 9 6 3-phase 380~480V 12 17 25 27 35 42 56 67 87 3-phase 380 to 480 V ± 10%(342~528 V) 110 150 101 122 ± 5%(47~63 Hz) Natural 2.7 3.2 4.5 6.8 8 10 13 Fan Cooled 13 13 13 36 36 36 50 General Specifications 1 V/f curve; 2 V/f+PG; 3 SVC; 4 FOC+PG; 5 TQR+PG Starting torque is 150% at 0.5Hz and 0Hz with FOC + PG control mode 1:100 Sensorless vector (up to 1:1000 when using PG card) ± 0.5% Sensorless vector (up to ± 0.02% when using PG card) 5Hz (up to 30Hz for vector control) 0.00 to 600.00Hz Digital command ± 0.005%, analog command ± 0.5% Digital command 50 ± 0.01Hz, analog command: 1/4096(12-bit) of the max. output frequency Max. is 200% torque current ± 5% 0.00 to 600.00/0.0 to 6000.0 seconds Adjustable V/f curve using 4 independent points and square curve ± 10V, 4~20mA, pulse input About 20% Electronic thermal relay protection English- 2