2. Terminals descriptions
Terminal Symbols
J3
VP
Descriptions
Specifications
Power source of encoder
(use SW2 to switch 12V/5V)
Power source common for
encoder
Sine line drive input
(incremental signal)
0V
A+, A-,
B+, B-
Voltage: +5VDC±5% or +8.3 VDC±6%
Current: 250mA max.
Reference level of the power of encoder
Input frequency: 40kHz max.
360 0 el.
0
A
900 el.
0
+SIN, +COS Sine line drive input
REFSIN,
(incremental signal)
REFCOS
0.8....1.2Vss
(~
~ 1Vss; Z 0 =120
B
Input frequency: 20kHz max.
SIN
0.9...1.1V
REFSIN/REFCOS
CLOCK+,
CLOCK line drive output
CLOCKData+, DataTB1
Line Driver RS422 Level output
RS485 communication interface
Terminal resistor: about 130 Ω
A /O, Signal output for PG
feedback card and can be
Line Driver RS422 Level output
B/O, B /O used as a frequency divider.
A/O,
TB2 OA
OB
Open collector output signal ・Transistor open collector output
and can be used as a
・Max. 24VDC, 30mA
frequency divider
・VOL≦1.5V(IOL=30mA)
・IOH≦200μA(VOH=24VDC)
Open collector output
Reference level of NPN transistor open
common
collector output
Connected to the grounding of the power
Grounding
of the AC motor drive and used for PG
shielding
GND
J4
4. Output Signal Setting of the Frequency Divider
ON
0
1
1 2
Division factor: setting for division factor n:
1~31
RST
BIT4
BIT3
BIT2
BIT1
BIT0
Division Factor
O/MODE
It generates the output signal of division factor O/MODE: output type setting of the division
“n” after dealing with the input pulse. Please
pulse
set by the switch SW1 on the card.
RST: clock reset bit
ON
3 4
5
1
Settings and explanations
B-36
)