Table 9. Common Firmware Error Codes (continued)
Error Code
Description
Action/ Possible Failing FRU
B1xx 4645
Non-processor VPD failure
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4646
General VPD failure
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4647
The machine type and model
reported by the CEC hardware do not
match the machine type and model
stored in the VPD module on the
operator panel.
Replace the operator panel, Location:
L1. Do not swap the VPD module
from the old op panel onto the new
op panel; leave the new,
unprogrammed VPD module on the
new op panel. Call service support to
get instructions on reprogramming
the machine type and model and the
system serial number in the VPD
module.
B1xx 4648
CPU backplane VPD failure
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4650
A system processor failure has been Information only. If the problem
detected by the service processor. All persists, check the error logs for
system processors have been reset
other fault indications.
in an attempt to recover operations.
If no other fault indications are found,
go to “MAP 1540: Minimum
Configuration” on page 57 and run
the minimum configuration.
B1xx 4651
CPU VPD fault
Processor card, Location: P1-C1
B1xx 4660
Memory subsystem failure (cannot
isolate)
Go to “MAP 1540: Minimum
Configuration” on page 57
B1xx 4661
Memory riser card VPD failure
Go to “MAP 1540: Minimum
Configuration” on page 57
B1xx 4662
Memory DIMM VPD failure
Go to “MAP 1540: Minimum
Configuration” on page 57
B1xx 4670
Processor cooling
1. Check ambient temperature
2. Check air supply to fans
3. Check fans for proper installation
and operation
4. Check for unsupported cards
(that may be too hot)
5. Operator panel, Location: L1
Chapter 5. Error Code to FRU Index