03/2009 Overview of Alarms SINAMICS-Alarms Remedy: - check the parameterized line frequency and if required change (p0211). - check the alarm threshold (p0285). - check the line supply. - check the line supply quality. See also: p0211 (Rated line freq), p0285 (Line supply frequency undershot, alarm threshold) 206400 <location>Infeed: Line supply data identification selected/active Message value: - Drive object: A_INF, S_INF Reaction: NONE Acknowledge: NONE Cause: The line supply data identification is selected and active. The line inductance and the DC link capacitance are measured at the next pulse enable. See also: p3410 (Infeed identification method) Remedy: No remedial action required. 206500 <location>Infeed: Line synchronization not possible Message value: - Drive object: A_INF, S_INF Reaction: OFF2 (OFF1) Acknowledge: IMMEDIATELY (POWER ON) Cause: The line synchronization is not possible within the monitoring time. The infeed was re-synchronized to the line supply because it was interrupted due to a line frequency that was determined to be either too low or too high. After 20 attempts, synchronization - and therefore also the power-on operation - were interrupted. Remedy: - check the parameterized line frequency and if required change (p0211). - check the setting of the threshold values (p0284, p0285). - check the line supply. - when a Voltage Sensing Module (VSM) is used: check the line supply to the VSM terminals X521 or X522. - check the line supply quality. See also: p0211 (Rated line freq), p0284 (Line supply frequency exceeded, alarm threshold), p0285 (Line supply frequency undershot, alarm threshold) 206601 <location>Infeed: Current offset measurement interrupted Message value: %1 Drive object: A_INF, B_INF, S_INF Reaction: NONE Acknowledge: NONE Cause: Defective current measurement or a DC current is present during the offset measurement. Alarm value (r2124, interpret decimal): 1: Excessively high phase current has occurred during the current offset calibration. 2: The measured current offset is greater than the 3% of the maximum permissible converter current (e.g. due to a ground fault in the DC link). Remedy: Re alarm value = 1: - possible counter-measure if there is no line contactor: Power up an adequately long time before OFF1 = 1. Re alarm value = 2: - defective current measurement or a DC current is present during the offset measurement. - check the DC link for a ground fault. 206602 <location>Infeed: Current offset measurement not possible Message value: - Drive object: A_INF, B_INF, S_INF Reaction: NONE Acknowledge: NONE © Siemens AG 2009 All Rights Reserved SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009 2-731
Related documents
Manual de diagnósticos - Industry Support Siemens
Manual de diagnóstico Alarmes
Manual de diagnóstico, Alarmes - Service, Support
Manual de diagnóstico, Alarmes - Service, Support
Display - Internet
Manual de diagnóstico, Alarmes - Service, Support
Programming Manual Measuring cycles HMI sl
COMP-MALL GmbH www.comp
Manuale utente
List Manual G120C - Service, Support
List Manual G120C
Siemens SINUMERIK 802D sl Operator`s manual