Parameters Parameter list Value: 0: 1: 2: 128: Non-ventilated Forced cooling Liquid cooling No fan Dependency: For 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311. Caution: When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Information in p0300 should be carefully observed when removing write protection. Note: The parameter influences the thermal 3-mass motor model. 1LA7 motors, frame size 56 are operated without fan. p0340[0...n] Automatic calculation, motor/control parameters / Calc auto par Access level: 2 Calculated: - Data type: Integer16 Can be changed: C(3), T Scaling: - Data set: DDS, p0180 Units group: - Unit selection: - Min 0 Max 5 Factory setting 0 Description: Setting to automatically calculate motor parameters and U/f open-loop and closed-loop control parameters from the rating plate data. Value: 0: 1: 2: 3: 4: 5: Notice: After the value has been modified, no further parameter modifications can be made and the status is shown in r3996. Modifications can be made again when r3996 = 0. No calculation Complete calculation Calculation of equivalent circuit diagram parameters Calculation of closed-loop control parameters Calculation of controller parameters Calculation of technological limits and threshold values The following parameters are influenced using p0340: p0340 = 1: --> All of the parameters influenced for p0340 = 2, 3, 4, 5 --> p0341, p0342, p0344, p0640, p1082, p1231, p1232, p1349, p1611, p1726, p1909, p1959, p2000, p2001, p2002, p2003, p3927, p3928 p0340 = 2: --> p0350, p0354 ... p0360 --> p0625 (matching p0350) p0340 = 3: --> All of the parameters influenced for p0340 = 4, 5 --> p0346, p0347, p0622, p1320 ... p1327, p1582, p1755 p0340 = 4: --> p1290, p1292, p1338, p1340, p1341, p1345, p1346, p1470, p1472, p1764, p1767 p0340 = 5: --> p1037, p1038, p1520, p1521, p1530, p1531, p1802, p1803, p2390, p2392, p2393 Note: p0340 = 1 contains the calculations of p0340 = 2, 3, 4, 5. p0340 = 2 calculates the motor parameters (p0350 ... p0360). p0340 = 3 contains the calculations of p0340 = 4, 5. p0340 = 4 only calculates the controller parameters. p0340 = 5 only calculates the controller limits. When quick commissioning is exited using p3900 > 0, p0340 is automatically set to 1. At the end of the calculations, p0340 is automatically set to 0. 1-54 © Siemens AG 2012 All Rights Reserved SINAMICS G120C List Manual (LH13), 01/2012, A5E03052632B AB
Related documents
List Manual G120C
SINAMICS G120C SINAMICS
ComBridge Studio Visual Editor V 1.6.6 User Manual
Display - Internet
Bunn A-10 Specifications
Diagnostics Manual - Service, Support
Manual - AudioVisual Online
5 - Advanced Test Equipment Rentals
Descarga
Conversores de frequência montados em unidade de
Siemens CU230P-2 Technical data
Siemens SINAMICS G120C