Download RAM SBeam v5.0 User Manual

Transcript
Chapter 5 Output and Creating Reports
5.3 Beam Design Output
# of Studs
Number of studs required for the design of the beam. The number of studs is given for
full composite action (or maximum, if full composite action cannot be obtained),
partial composite action and the actual number used. Unless otherwise specified by the
user the actual and the partial number of studs will be the same. When there exists a
point load on the designed beam, a series of studs may be listed with a comma
separating them. Each number represents the number of studs required between each
point load or segment, starting at the left support.
Number of Stud Rows
Number of rows of studs necessary to place the number of studs called for.
Percent of Full Composite Action
Percent of full composite action that will be obtained if the number and distribution of
studs conform to that specified for Actual. It represents the worst condition from any
segment.
User Defined Unbraced Top Flange Segments
This information will not be listed if the beam has been specified as Non-composite Unbraced
Top Flange, and will only be listed if there are segments of the top flange that have been
explicitly specified as unbraced.
From / To
Indicates the beginning and end of each segment of top flange that is unbraced.
User Defined Flange Brace Points
This information will be listed if there are any user-specified flange brace points (points at
which the flange is braced against lateral translation or buckling).
Dist
Location of the flange brace point, measured from the left end of the beam.
Top
Indicates whether or not the top flange is braced at that location.
Bottom
Indicates whether or not the bottom flange is braced at that location.
Loading Information - Point Loads
See Allowable Stress Design AISC for a description of this information.
Loading Information - Line Loads
See Allowable Stress Design AISC for a description of this information.
Shear
Max Vfx
Maximum shear force in the member and the load combination that resulted in this
load.
Vrx
Shear capacity of the member.
User Manual — 39