Download RAM SBeam v5.0 User Manual
Transcript
Chapter 5 Output and Creating Reports 5.3 Beam Design Output # of Studs Number of studs required for the design of the beam. The number of studs is given for full composite action (or maximum, if full composite action cannot be obtained), partial composite action and the actual number used. Unless otherwise specified by the user the actual and the partial number of studs will be the same. When there exists a point load on the designed beam, a series of studs may be listed with a comma separating them. Each number represents the number of studs required between each point load or segment, starting at the left support. Number of Stud Rows Number of rows of studs necessary to place the number of studs called for. Percent of Full Composite Action Percent of full composite action that will be obtained if the number and distribution of studs conform to that specified for Actual. It represents the worst condition from any segment. User Defined Unbraced Top Flange Segments This information will not be listed if the beam has been specified as Non-composite Unbraced Top Flange, and will only be listed if there are segments of the top flange that have been explicitly specified as unbraced. From / To Indicates the beginning and end of each segment of top flange that is unbraced. User Defined Flange Brace Points This information will be listed if there are any user-specified flange brace points (points at which the flange is braced against lateral translation or buckling). Dist Location of the flange brace point, measured from the left end of the beam. Top Indicates whether or not the top flange is braced at that location. Bottom Indicates whether or not the bottom flange is braced at that location. Loading Information - Point Loads See Allowable Stress Design AISC for a description of this information. Loading Information - Line Loads See Allowable Stress Design AISC for a description of this information. Shear Max Vfx Maximum shear force in the member and the load combination that resulted in this load. Vrx Shear capacity of the member. User Manual — 39