Download Technical Manual
Transcript
If you are using an older generation CPU board that does not generate pSTVAL*, then you will need to make a small modification to the System Support 1. Proceed as follows: Locate Jll. It is located near the edge connector in approximately the center of the board. Jll has three pads labeled A, C and B. If you look on the back (solder) side of the board you will notice that there is a small trace connecting pad B to pad C. Using an XACTO knife, carefully cut this trace. Take care not to damage any other traces on the PC board. Then install a jumper between pads A and C. That completes this modification. Use of SLAVE CLR* Instead of RESET* - The S-100 signal SLAVE CLR* (bus pin 54) is specifically designated for clearing slave devices (the System Support 1 is a slave device). However, it is usually more convenient in most systems to use RESET* instead of SLAVE CLR*. The System Support 1 is currently wired to use RESET* to clear the various circuits on the board. Provision has been made to use SLAVE CLR* instead of RESET* if you so desire. To do this, locate J9 and J12. J9 is a single jumper pad located at the bottom left-hand corner of the board just above the edge connector fingers. J12 is also located at the bottom of the board just above the edge connector fingers, but near the center of the board. J12 has two pads that are connected together by a trace on the back (solder) side of the board. This trace must be cut with an XACTO knife. Be sure not to damage any other traces. Then, using a length of insulated wire (such as wire-wrap wire), install a jumper between the pad of J9 and the left-most pad of J12 (the one closest to the "C"). This will cause the circuitry on the board to be cleared in response to POC* and SLAVE CLR*. PWRFAIL* and NMI* - The System Support 1 generates the S-100 PWRFAIL* signal which is used to indicate that a loss of power is imminent. You will usually want this signal to cause a nonmaskable interrupt (NMI*) to the CPU. The CPU can then save any data it deems relevant. Provision has been made to jumper the PWRFAIL* signal to the NMI* line on the S-100 Bus. Thus both PWRFAIL* and NMI* would be asserted low about 15 milliseconds before the regulators in the system drift out of regulation. (The exact time will depend on your system's power supply and loading.) If you desire to have the PWRFAIL* signal cause an NMI*, then install a jumper at location JI0. JI0 is located at the bottom left hand side of the board, just above the edge connector fingers. If you don't care about the PWRFAIL* signal, then you need not do anything with JI0. As an option, the PWRFAIL* signal is available at the right-most pad of JI0. It could conceivably be hooked to any other S-100 interrupt pin via a header at J7. It should be mentioned, however, that this would not be a good practice because any of the other interrupts could be "masked" at the time of power failure, thus defeating the purpose of the PWRFAIL* signal. 17