If you are using an older generation CPU board that does not
generate pSTVAL*, then you will need to make a small modification
to the System Support 1. Proceed as follows:
Locate Jll. It is located near the edge connector in approximately
the center of the board. Jll has three pads labeled A, C and B.
If you look on the back (solder) side of the board you will notice
that there is a small trace connecting pad B to pad C. Using an
XACTO knife, carefully cut this trace. Take care not to damage any
other traces on the PC board. Then install a jumper between pads A
and C. That completes this modification.
Use of SLAVE CLR* Instead of RESET* - The S-100 signal SLAVE CLR*
(bus pin 54) is specifically designated for clearing slave devices
(the System Support 1 is a slave device). However, it is usually
more convenient in most systems to use RESET* instead of SLAVE
CLR*. The System Support 1 is currently wired to use RESET* to
clear the various circuits on the board. Provision has been made
to use SLAVE CLR* instead of RESET* if you so desire.
To do this, locate J9 and J12. J9 is a single jumper pad located
at the bottom left-hand corner of the board just above the edge
connector fingers. J12 is also located at the bottom of the board
just above the edge connector fingers, but near the center of the
board. J12 has two pads that are connected together by a trace on
the back (solder) side of the board. This trace must be cut with
an XACTO knife. Be sure not to damage any other traces. Then,
using a length of insulated wire (such as wire-wrap wire), install
a jumper between the pad of J9 and the left-most pad of J12 (the
one closest to the "C"). This will cause the circuitry on the
board to be cleared in response to POC* and SLAVE CLR*.
PWRFAIL* and NMI* - The System Support 1 generates the S-100
PWRFAIL* signal which is used to indicate that a loss of power is
imminent.
You will usually want this signal to cause a nonmaskable interrupt (NMI*) to the CPU. The CPU can then save any
data it deems relevant. Provision has been made to jumper the
PWRFAIL* signal to the NMI* line on the S-100 Bus. Thus both
PWRFAIL* and NMI* would be asserted low about 15 milliseconds
before the regulators in the system drift out of regulation. (The
exact time will depend on your system's power supply and loading.)
If you desire to have the PWRFAIL* signal cause an NMI*, then
install a jumper at location JI0. JI0 is located at the bottom
left hand side of the board, just above the edge connector fingers.
If you don't care about the PWRFAIL* signal, then you need not do
anything with JI0.
As an option, the PWRFAIL* signal is available at the right-most
pad of JI0. It could conceivably be hooked to any other S-100
interrupt pin via a header at J7. It should be mentioned, however,
that this would not be a good practice because any of the other
interrupts could be "masked" at the time of power failure, thus
defeating the purpose of the PWRFAIL* signal.