5 - Troubleshooting Display Message Causes Solution E022 Self-Test Error 4 Relay self- test timeout 011C5 Time taken to execute the autotest carried out on the relays of the DC_AC circuit part (inverter) is too long. This may indicate a problem associated with the aforesaid relays. E023 The error is generated if the diDC inj error rect component of the current Dc-Injection out of supplied to the grid exceeds the range threshold of 0.5% of the rated operating current. The error does not stop the inverter, instead tries to connect to the grid again. Sporadic repetition of the error is a sign of large grid distortions or sudden changes in sunlight, whereas systematic repetition of the error warning will be a sign of an inverter fault. E024 Error inside the inverter Internal error - 69 - Error inside the inverter that cannot be checked externally. If the problem persists (after switching the inverter off and then on again), contact customer service. If the grid voltage is strongly distorted, report this anomaly to the utility company for the resolution of the problem If there is an inverter fault, contact customer service. Error inside the inverter that cannot be checked externally. If the problem persists (after switching the inverter off and then on again), contact customer service.