Causes of accelerated ageing Masterpact NT and NW Maintenance guide Operating conditions Operating conditions directly affect the service life of switchgear due to the limited electrical and mechanical endurance levels of the various subassemblies. Operating conditions include: b vibrations, b the number of operating cycles, b the interrupted currents. Vibrations Influence Premature deterioration of contact surfaces (clusters and main contacts). Untightening of bolted assemblies. Wear of mechanical parts. Appearance of fretting corrosion on auxiliary connections. Breaking of connectors on large electronic components (e.g. large capacitors). Wear of thumbwheel contacts on the control unit. Appearance Consequences Not identifiable. Not identifiable. Not identifiable. Increase in mechanical play. Broken springs. Increase in mechanical play between parts. Erroneous information or loss of continuity in data or supply, excessive temperature rise. Failure of protection function. Not identifiable. Nuisance tripping or no tripping. 0.2 g to 0.5 g Reduced service life. 0.5 g to 0.7 g Significant increase in incidents. Carry out more frequent periodic checks (see table). Carry out more frequent periodic checks (see page 10). Check in particular the tightness of connections. No particular precautions required. Install switchgear on a rubber mounting bush. Not identifiable. Increased device temperature rise. Not identifiable. Thresholds (g) y 0.2 g Normal condition, no impact on service life. > 0.7 g Forbidden for standard devices. Recommendation Preventive maintenance Implement the standard program. Installation No particular precautions required. Use special devices. Number of operating cycles Influence The number of operating cycles depends directly on the electrical and mechanical endurance of the device. Appearance Device service life depends on the daily number of operating cycles. y 60 cycles per month Corresponds to two cycles per day. For an endurance of 10000 cycles and an interrupted current of less than 0.4 In, the service life is 13 years. Device service life depends on the daily number of operating cycles. y 120 cycles per month Corresponds to four cycles per day. For an endurance of 10000 cycles and an interrupted current of less than 0.4 In, the service life is 7 years. 63398A-64 y 30 cycles per month Corresponds to one cycle per day. For an endurance of 10000 cycles and an interrupted current of less than 0.4 In, the service life is 27 years. Consequences 22 LVPED508016ENp1_p28.indd 22 LVPED508016EN - 11/2008 25/11/2008 15:46:20