Download Masterpact Maintainence guide

Transcript
Causes of accelerated ageing
Masterpact NT and NW
Maintenance guide
Operating conditions
Operating conditions directly affect the service life of switchgear due to the limited
electrical and mechanical endurance levels of the various subassemblies. Operating
conditions include:
b vibrations,
b the number of operating cycles,
b the interrupted currents.
Vibrations
Influence
Premature deterioration of contact
surfaces (clusters and main contacts).
Untightening of bolted assemblies.
Wear of mechanical parts.
Appearance of fretting corrosion on
auxiliary connections.
Breaking of connectors on large
electronic components (e.g. large
capacitors).
Wear of thumbwheel contacts on the
control unit.
Appearance
Consequences
Not identifiable.
Not identifiable.
Not identifiable.
Increase in mechanical play.
Broken springs.
Increase in mechanical play between parts.
Erroneous information or loss of continuity in data or supply, excessive
temperature rise.
Failure of protection function.
Not identifiable.
Nuisance tripping or no tripping.
0.2 g to 0.5 g
Reduced service life.
0.5 g to 0.7 g
Significant increase in incidents.
Carry out more frequent periodic
checks (see table).
Carry out more frequent periodic
checks (see page 10).
Check in particular the tightness of
connections.
No particular precautions required.
Install switchgear on a rubber
mounting bush.
Not identifiable.
Increased device temperature rise.
Not identifiable.
Thresholds (g)
y 0.2 g
Normal condition, no impact on
service life.
> 0.7 g
Forbidden for standard devices.
Recommendation
Preventive maintenance
Implement the standard program.
Installation
No particular precautions required.
Use special devices.
Number of operating cycles
Influence
The number of operating cycles depends directly on
the electrical and mechanical endurance of the
device.
Appearance
Device service life depends on the daily number of operating cycles.
y 60 cycles per month
Corresponds to two cycles per day.
For an endurance of 10000 cycles and an
interrupted current of less than 0.4 In, the service
life is 13 years.
Device service life depends on the daily number of
operating cycles.
y 120 cycles per month
Corresponds to four cycles per day.
For an endurance of 10000 cycles and an
interrupted current of less than 0.4 In, the service
life is 7 years.
63398A-64
y 30 cycles per month
Corresponds to one cycle per day.
For an endurance of 10000 cycles and an
interrupted current of less than 0.4 In, the service
life is 27 years.
Consequences
22
LVPED508016ENp1_p28.indd 22
LVPED508016EN - 11/2008
25/11/2008 15:46:20