Download System 236E Installation Instructions
Transcript
System 236E Installation Instructions DEFAULT VALUES (cont.) Option Location Timing Entry time: 60 seconds, prewarn Exit time: 30 seconds, prewarn Bell time: 5 minutes Loop Restore Type Loop Shunting Enable Loop Shunt Report Code Low Battery Report Code Low Battery Restore Report Code Master Code Opening Report Code Opening/Closing Report Receiver Select Panic Audible Type Panic Report Code Panic Report Receiver Select Phone Ring Type Receiver #1 Message Format Receiver #1 Phone Number Receiver #1 Receive Format Receiver #2 Message Format Receiver #2 Phone Number Receiver #2 Receive Format RPS Enable RPS Phone Number Set Test Report Countdown Timer Test Report Code Test Report Interval Test Report Receiver Select Trouble Report Code Trouble Restore Code Unit Status Report Code User Arming Type User Combinations User Code Pager Enable Watchdog Reset Report Code 1D - 22 (3) 24 (1 - 6) 15 (2) 18 (5) 18 (6) 01 (1 - 4) 16 (2) 16 (1) 19 (4) 19 (1 - 2) 19 (3) 09 (5) 0A (2) 0C - 0E (1 - 6) 0A (1) 0A (4) 0F - 11 (1 - 6) 0A (3) 09 (3) 12 - 14 (1 - 6) A0 (1) 1A (1 - 2) 1A (4) 1A (3) 15 (4) 15 (5) 17 (1) 07 (1 - 6) 01 - 06 (1 - 4) 26 (1 - 6) 17 (2) Unit Control: Local system: yes Dynamic battery test: off PROGRAMMING OPTIONS The following is an alphabetical listing of all System 236E programming options, including Command Locations and Digit Positions. Digit Positions are inside parentheses ( ). Option AC Fail Report Code AC Line Frequency AC Restore Report Code Account Number Audible Time Autohome Enable Bell Fuse Fail Report Code Bell Fuse Restore Report Code Cancel Report Code Closing Report Code Combination Command Completed Programming Report Code Daily Battery Test Enable Default Installer Combination Delay Before Dial Enable Delay Before Dial Time Dial Attempts Dial Type Disable Instant/Home Exit Delay Disable Loop LEDs Door Chime Enable Duress Code Duress Report Code Entry Delay Time Event Report Receiver Select Exit Delay Time Failed To Communicate Report Code Faulted Arming Type Installer Combination Keypad Activated Pager Enable Keypad Pager Report Code Keypad RPS Enable Local System Only Loop Alarm Report Code Loop Arming Type Loop Audible Type Loop Circuit Type Loop Receiver Select Loop Response Time Loop Restore Reporting Code Location 18 (3) 08 (6) 18 (4) 0B (1 - 6) 1B (3) 1B (6) 18 (1) 18 (2) 15 (3) 16 (3) 08 (5) 17 (4) 08 (4) 08 (3) 25 (1 - 6) 1B (4) 09 (2) 09 (6) 1B (5) 08 (1) 23 (1 - 6) 28 (1 - 4) 16 (4 - 5) 1B (1) 15 (1) 1B (2) 17 (3) 08 (2) 00 (1 - 6) 27 (1) 27 (2 - 6) 09 (4) 09 (1) 1C (1 - 6) 1D - 22 (4) 1D - 22 (5) 1D - 22 (6) 1D - 22 (2) 1D - 22 (1) 15 (5) PROGRAMMING THE PANEL You can program the System 236E from the LED keypad or remotely using the Commander II software. This manual provides you with a brief description of each programming option beginning on page 8. Remote Programming information can be found in the Commander II/Monitor II Operating Manual. To Start Keypad Programming Key in the [Installer Combination][*][0][#]. The default installer combination is: 0 1 2 3 4 5. On the LED keypad, the ARM, SERVICE, and AC LED's will flash to indicate programming mode. Programming with the LED Keypad Programming with the LED keypad is a one-step process. Key in the two-digit address (Command Location) followed by the desired programming values (program data), then press the [#] key to store the data. The LED keypad does not display programmed values. If you are not sure that the correct programming values have been entered, program the Command Location again. 7