Download System 236E Installation Instructions

Transcript
System 236E Installation Instructions
DEFAULT VALUES (cont.)
Option
Location
Timing
Entry time: 60 seconds, prewarn
Exit time: 30 seconds, prewarn
Bell time: 5 minutes
Loop Restore Type
Loop Shunting Enable
Loop Shunt Report Code
Low Battery Report Code
Low Battery Restore Report Code
Master Code
Opening Report Code
Opening/Closing Report Receiver Select
Panic Audible Type
Panic Report Code
Panic Report Receiver Select
Phone Ring Type
Receiver #1 Message Format
Receiver #1 Phone Number
Receiver #1 Receive Format
Receiver #2 Message Format
Receiver #2 Phone Number
Receiver #2 Receive Format
RPS Enable
RPS Phone Number
Set Test Report Countdown Timer
Test Report Code
Test Report Interval
Test Report Receiver Select
Trouble Report Code
Trouble Restore Code
Unit Status Report Code
User Arming Type
User Combinations
User Code Pager Enable
Watchdog Reset Report Code
1D - 22 (3)
24 (1 - 6)
15 (2)
18 (5)
18 (6)
01 (1 - 4)
16 (2)
16 (1)
19 (4)
19 (1 - 2)
19 (3)
09 (5)
0A (2)
0C - 0E (1 - 6)
0A (1)
0A (4)
0F - 11 (1 - 6)
0A (3)
09 (3)
12 - 14 (1 - 6)
A0 (1)
1A (1 - 2)
1A (4)
1A (3)
15 (4)
15 (5)
17 (1)
07 (1 - 6)
01 - 06 (1 - 4)
26 (1 - 6)
17 (2)
Unit Control:
Local system: yes
Dynamic battery test: off
PROGRAMMING OPTIONS
The following is an alphabetical listing of all System 236E programming
options, including Command Locations and Digit Positions. Digit
Positions are inside parentheses ( ).
Option
AC Fail Report Code
AC Line Frequency
AC Restore Report Code
Account Number
Audible Time
Autohome Enable
Bell Fuse Fail Report Code
Bell Fuse Restore Report Code
Cancel Report Code
Closing Report Code
Combination Command
Completed Programming Report Code
Daily Battery Test Enable
Default Installer Combination
Delay Before Dial Enable
Delay Before Dial Time
Dial Attempts
Dial Type
Disable Instant/Home Exit Delay
Disable Loop LEDs
Door Chime Enable
Duress Code
Duress Report Code
Entry Delay Time
Event Report Receiver Select
Exit Delay Time
Failed To Communicate Report Code
Faulted Arming Type
Installer Combination
Keypad Activated Pager Enable
Keypad Pager Report Code
Keypad RPS Enable
Local System Only
Loop Alarm Report Code
Loop Arming Type
Loop Audible Type
Loop Circuit Type
Loop Receiver Select
Loop Response Time
Loop Restore Reporting Code
Location
18 (3)
08 (6)
18 (4)
0B (1 - 6)
1B (3)
1B (6)
18 (1)
18 (2)
15 (3)
16 (3)
08 (5)
17 (4)
08 (4)
08 (3)
25 (1 - 6)
1B (4)
09 (2)
09 (6)
1B (5)
08 (1)
23 (1 - 6)
28 (1 - 4)
16 (4 - 5)
1B (1)
15 (1)
1B (2)
17 (3)
08 (2)
00 (1 - 6)
27 (1)
27 (2 - 6)
09 (4)
09 (1)
1C (1 - 6)
1D - 22 (4)
1D - 22 (5)
1D - 22 (6)
1D - 22 (2)
1D - 22 (1)
15 (5)
PROGRAMMING THE PANEL
You can program the System 236E from the LED keypad or
remotely using the Commander II software. This manual provides
you with a brief description of each programming option beginning on page 8. Remote Programming information can be found
in the Commander II/Monitor II Operating Manual.
To Start Keypad Programming
Key in the [Installer Combination][*][0][#]. The default installer
combination is: 0 1 2 3 4 5. On the LED keypad, the ARM,
SERVICE, and AC LED's will flash to indicate programming mode.
Programming with the LED Keypad
Programming with the LED keypad is a one-step process. Key in
the two-digit address (Command Location) followed by the
desired programming values (program data), then press the [#]
key to store the data. The LED keypad does not display programmed values. If you are not sure that the correct programming values have been entered, program the Command Location
again.
7