negative N directions. In other words, all movement along the N axis will
be prevented.
- By placing a check mark in this check box, the User instructs TRIFLEX
to apply a one directional restraint acting in the - Y direction. These
restraints resist movement in the positive N direction and allow movement
in the negative N direction.
Limit Stops - By placing a check mark in this check box, the User instructs
TRIFLEX to apply limit stop acting along the N axis. For more details
concerning the application of a typical limit stop, see the discussion for limit stop
acting along the L axis.
When a check mark is placed in the limit stop check box, the labels of the
following three fields will be altered to allow the User to enter the following data:
Upper Limit – In this field, the User may specify the upper limit for the limit
stop along the N axis. The upper limit will be the most positive value for the limit
stop.
Lower Limit – In this field, the User may specify the lower limit for the limit
stop along the N axis. The lower limit will be the least positive value for the limit
stop.
Stiffness - In this field, the User may specify the stiffness of the limit stop along
the N axis. This stiffness will only come into effect after the pipe has deflected
freely to the limit position of the limit stop. If the User specifies no value for
stiffness, TRIFLEX will assume the limit stop restraint to be totally rigid. To
enter a definable value for the stiffness, the User must type the desired numerical
value in this field.
Note: G Axis check can only be placed in one check box for each translational
axis action. The G axis is normal to the pipe and the most horizontal.
+ And - By placing a check mark in this check box, the User instructs
TRIFLEX to apply a two directional translational restraint acting in the +
and - G direction. These restraints resist movement in the positive and
negative G directions. In other words, all movement along the Z-axis will
be prevented.
Limit Stops - By placing a check mark in this check box, the User instructs
TRIFLEX to apply limit stop acting along the G axis. For more details
concerning the application of a typical limit stop, see the discussion for limit stop
acting along the L axis
When a check mark is placed in the limit stop check box, the labels of the
following three fields will be altered to allow the User to enter the following data:
155