Chapter 3
+ By placing a check mark in this check box, the User instructs TRIFLEX
to apply a one directional restraint acting in the + A direction. These
restraints resist movement in the negative a direction and allow movement
in the positive a direction.
+ And - By placing a check mark in this check box, the User instructs
TRIFLEX to apply a two directional translational restraint acting in the +
and - A direction. These restraints resist movement in the positive and
negative a direction. In other words, all movement along the A axis will
be prevented.
- By placing a check mark in this check box, the User instructs TRIFLEX
to apply a one directional restraint acting in the - A direction. These
restraints resist movement in the positive a direction and allow movement
in the negative a direction.
Limit Stops - Limit stops may not be specified when the User has selected the A,
B, C coordinate system. Therefore, this data field is grayed out.
When no check mark is placed in any of the check boxes at the top of this column,
the labels of the three fields following the Limit Stop check box will be as set
forth below and will allow the User to enter the following data:
Movement - In this field, the User may define a Movement that the User wishes
to impose on the pipe at the restraint location. If the Movement is to be applied to
the pipe in the negative a direction, then the User must enter the numerical value
preceded by a negative sign. When the User has entered a Movement along the A
axis, the Force and Stiffness fields are grayed out in order to prevent the User
from entering data in these fields. When the User enters a movement in this field,
TRIFLEX will impose this Movement on the piping system and will hold the
piping system at that position in the analysis.
Force - In this field, the User may define a Force that the User wishes to impose
on the pipe at the restraint location. If the Force is to be applied to the pipe in the
negative a direction, then the User must enter the numerical value preceded by a
negative sign. If the Force is to be applied to the pipe in the positive a direction,
then the User need not enter any sign. When a User has entered a Force along the
A axis, the Stiffness field will default to Free and the Movement field will be
grayed out in order to prevent a movement from being entered in this field by the
User. When the User enters a numerical value for the Force in this field,
TRIFLEX will impose this force on the piping system and will continue to apply
this Force no matter where the piping system moves.
Stiffness - The default for the Stiffness field is “FREE”. To enter a definable
value for the stiffness, the User must type the desired numerical value in this field.
To make the stiffness Free after having entered some other value, simply type F
and TRIFLEX will display the word FREE.
159