9.11. EMERGENCY POWER OPERATION: REGISTER DM0091 DM0285 DM0405 DM3100 DM3101… DM3110 DM3111… DESCRIPTION Max. speed, (2 floors and +) allowed on emergency power. (Yes = 0 no = 1) GEN1 and GEN2 signals reversing on normal power. (0 = N.O. 1= N.C). Number of elevators to control during emergency power operation. 1st elevator of the group to return the main floor. 2nd elevator of the group to return the main floor. 1st elevator of the group that returns in automatic mode after all elevators are at the main floor. With the separate dispatcher, the CJ1M IO uses the same registers. 2nd elevator of the group that returns in automatic mode after all elevators are at the main floor if the first one before is faulty. With the separate dispatcher, the CJ1M IO uses the same registers. UNIT n/a n/a n/a n/a n/a n/a n/a 9.12. PRIORITY SERVICE (BLUE CODE AND FREE CAR): REGISTRE DM1412 DM1413 DM1421 DM1422 DM1423 DM1425 DESCRIPTION Blue code reset timer if no movement was detected. ( protection ) Blue code, time allowed to turn the key inside the car before returning to automatic operation. Free car, operation buzzer off delay when arriving at the hall call level. Free car, delay before car call acceptance when arriving at the floor, door opens. Free car, delay before returning to automatic operation if no car calls entered. Free car, final delay upon arrived at destination. After that delay, the car returns in automatic. UNITÉ 0.1sec 0.1sec 0.1sec 0.1sec 0.1sec 0.1sec 9.13. POSITIONNING/SPEED/BOTTOM SWITCHES: REGISTER DM 0029 DM 0094 DM 0132 DM 0133 DM 0255 DM 0256 DM 0290 DM 0483 DM 0490 DM 0492 DM 5800 DM 5801 DESCRIPTION Disables the sensors of code bar (P1, P2, P3, etc.) (Disable = 1234 Activated = 0) Buffer test sequence allowed in maintenance. (1= Activated) Hole number for deceleration distance for one floor run rides. (posi1000, position indicator level switching distance) Hole number for deceleration distance for two floor run rides and more. Bottom hoist way access zone distance (0.75’’/ hole). Top hoist way access zone distance (0.75’’/ hole). Actual elevator speed. Number of floors registered during the hoist way learning. Elevator actual floor position in holes. (0.75’’/ hole) Floor learning sequence activation. (Yes = 1234, No=0) (inspection) CJ1M, absolute position from 0 to 10 000 000 encoder pulses or perforated tape. 9-9 UNIT n/a n/a Holes Holes Holes Holes Ft/min n/a. Holes n/a n/a n/a