Download user`s manual elevator controller cj1m processor 1

Transcript
9.11. EMERGENCY POWER OPERATION:
REGISTER
DM0091
DM0285
DM0405
DM3100
DM3101…
DM3110
DM3111…
DESCRIPTION
Max. speed, (2 floors and +) allowed on emergency power. (Yes = 0 no
= 1)
GEN1 and GEN2 signals reversing on normal power.
(0 = N.O. 1= N.C).
Number of elevators to control during emergency power operation.
1st elevator of the group to return the main floor.
2nd elevator of the group to return the main floor.
1st elevator of the group that returns in automatic mode after all elevators
are at the main floor. With the separate dispatcher, the CJ1M IO uses the
same registers.
2nd elevator of the group that returns in automatic mode after all elevators
are at the main floor if the first one before is faulty. With the separate
dispatcher, the CJ1M IO uses the same registers.
UNIT
n/a
n/a
n/a
n/a
n/a
n/a
n/a
9.12. PRIORITY SERVICE (BLUE CODE AND FREE CAR):
REGISTRE
DM1412
DM1413
DM1421
DM1422
DM1423
DM1425
DESCRIPTION
Blue code reset timer if no movement was detected. ( protection )
Blue code, time allowed to turn the key inside the car before returning to
automatic operation.
Free car, operation buzzer off delay when arriving at the hall call level.
Free car, delay before car call acceptance when arriving at the floor, door
opens.
Free car, delay before returning to automatic operation if no car calls
entered.
Free car, final delay upon arrived at destination. After that delay, the car
returns in automatic.
UNITÉ
0.1sec
0.1sec
0.1sec
0.1sec
0.1sec
0.1sec
9.13. POSITIONNING/SPEED/BOTTOM SWITCHES:
REGISTER
DM 0029
DM 0094
DM 0132
DM 0133
DM 0255
DM 0256
DM 0290
DM 0483
DM 0490
DM 0492
DM 5800
DM 5801
DESCRIPTION
Disables the sensors of code bar (P1, P2, P3, etc.) (Disable = 1234
Activated = 0)
Buffer test sequence allowed in maintenance. (1= Activated)
Hole number for deceleration distance for one floor run rides. (posi1000,
position indicator level switching distance)
Hole number for deceleration distance for two floor run rides and more.
Bottom hoist way access zone distance (0.75’’/ hole).
Top hoist way access zone distance (0.75’’/ hole).
Actual elevator speed.
Number of floors registered during the hoist way learning.
Elevator actual floor position in holes. (0.75’’/ hole)
Floor learning sequence activation. (Yes = 1234, No=0) (inspection)
CJ1M, absolute position from 0 to 10 000 000 encoder pulses or
perforated tape.
9-9
UNIT
n/a
n/a
Holes
Holes
Holes
Holes
Ft/min
n/a.
Holes
n/a
n/a
n/a