Download Controller Manual

Transcript
HM TEC
CONTROL MANUAL
Document No.:
HMC01-0003
Date:
21-Aug-09
Name:
W.M. Heo
PAGE:
59
ELEVATOR SAFETY TEST
■ Down Direction
■ Place Car at Intermediate Floor
■ Register Bottom Floor Call
■ As Elevator Levels at Bottom Landing manually pick MAIN Brake
■ Elevator will stop, level and begin to open doors.
■ Elevator will immediately drift and Emergency Brake will apply
■ Emergency Brake Indicator will go out
■ Elevator will come Out-of-Service
■ Reset Controller
■ Verify SAF is UP
7-9 Overspeed Test
■ Up Direction
■ Place Elevator at Bottom Landing
■ Turn Test Switch to Test Position
■ Record all Values in Lift Data in Inverter. (Drive Menu˃Lift˃Lift Configuration˃Lift Data)
■ Record Max Frequency Value (Drive Menu˃Motor Control˃Max Frequency)
■ Record High Speed Value (Drive Menu˃Setting˃High Speed)
■ Record Lift Top Speed Value (Drive Menu˃Lift˃Lift Configuration˃Lift Data˃Lift Top Speed)
Nominal Car Speed:
Capacity of the Lift:
Car Weight:
Counterweight
Comfort Accel.:
Lift Top Speed:
Acceleration Time:
■
■
■
■
■
Stop Length:
Lift Leveling Speed:
Lift Leveling Time:
Deceleration Length:
Max Frequency Value:
High Speed Value:
Lift Top Speed:
Increase Max Frequency, High Speed Value and Lift Top Speed 150%
On Service Tool select Overspeed Test then select Up
Elevator runs up and triggers GOV Overspeed Switch
Turn AUTO/INSP Switch to INSP Position
Return all values back to original settings and verify all Lift Data Values
■ Jump T1-1 to T1-2 and T1-24 to T1-27. Allows you to move car in Up direction only.
■ Reset Electrical Switch and Hammer on Governor
■ Remove all Jumpers
■ Reset Controller