4.6 4.6.3 Expansion Module MAC00-FD4 Node-id, Baud-rate and Termination setup The 10-way dip switch (SW1) is used to select the node ID and the Baud-rate. Switches 1-6 select the node ID, and switches 8-9 select the Baud-rate. The 2-way dip switch (SW2) is used to enable termination. When both switches are on, the termination is enabled. MAC00-FD4 Dip switch settings Mini dip-switch OFF Dip 1-6 - Node-id setting (address range 0-63) Dip 7 - Node-id set by software Dip 8-9 - Baud rate (Baud rate setting 125k to 500k) Dip-switch 10 is not used. Set in position “ON”. SW1 default settings = all set in position “ON” Dip 1-2 - Line termination Both set to ON = Term. enabled Both set to OFF = Term. disabled ON Rear side of the MAC00-FD4 expansion module 1 2 3 4 5 6 7 8 9 0 SW1 1 2 SW2 SW2 default settings = Both switches in position “OFF” Dip-switch location on the MAC00-FD4 Expansion module M12 external connectors Basic MAC motor housing Internal circuit boards TT1017GB 210 Dip Switches placed on the rear side of the module JVL Industri Elektronik A/S - User Manual - Integrated Servo Motors MAC050 - 3000