Explanation of I/O signals
9
9.1
Explanation of I/O signals
Input signals
The following input signals of the driver are photocoupler inputs. The signal state represents the
"ON: Carrying current" or "OFF: Not carrying current" state of the internal photocoupler rather than
the voltage level of the signal.
 START input
This signal starts the positioning operation.
Select the operation data number and turn the START input to ON to start positioning operation.
 M0, M1, M2 input
Select a desired operation data number based on a combination of ON/OFF status of the M0 to M2
inputs.
Operation data No.
0
1
2
3
4
5
6
7
M2
OFF
OFF
OFF
OFF
ON
ON
ON
ON
M1
OFF
OFF
ON
ON
OFF
OFF
ON
ON
M0
OFF
ON
OFF
ON
OFF
ON
OFF
ON
 ZHOME input
When the ZHOME input is turned ON, the motor will move to the home position set by the HOME
PRESET switch. Since it does not require sensors, return-to-home is possible at high-speed.
 FREE input
When the FREE input is turned ON, the motor current will be cut off. When an electromagnetic
brake motor is used, the electromagnetic brake will be released.
The motor output shaft can be rotated manually since the motor holding torque is lost.
Note
Do not turn the FREE input ON when driving a vertical load. Since the motor loses its holding
torque, the load may drop.
 STOP input
When the STOP input is turned ON, the motor will stop.
When resuming the operation, input the operation start signal to the driver after turning the STOP
input OFF.
 ALM-RST input
If the ALM-RST input is turned from OFF to ON while an alarm is generated, the alarm will be reset
(The alarm will be reset at the ON edge of the ALM-RST input).
Before resetting an alarm, turning the pulse input OFF, and then remove the cause of the alarm and
ensure safety.
Note that some alarms cannot be reset with the ALM-RST input.
−26−