Arguments
POSitive places a mark when the rising edge crosses the low threshold and
the falling edge re-crosses the low threshold without either edge ever crossing
the high threshold.
NEGative places a mark when the falling edge crosses the high threshold and
the rising edge re-crosses the high threshold without either edge ever crossing
the low threshold.
EITher places a mark on a runt of either polarity.
SEARCH:SEARCH<x>:TRIGger:A:RUNT:SOUrce
Sets or returns the source setting for a runt trigger search to determine where to
place a mark. <x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:RUNT:SOUrce
{CH1|CH2|CH3|CH4|MATH|REF}
SEARCH:SEARCH<x>:TRIGger:A:RUNT:SOUrce?
Arguments
CH1–CH4 specifies an input channel as the edge source.
MATH specifies the math waveform as the search source.
REF specifies the reference waveform as the search source.
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WHEn
Sets or returns the condition setting for a runt trigger search to determine where to
place a mark. <x> is the search number.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WHEn
{LESSthan|than|EQual|UNEQual|OCCURS}
SEARCH:SEARCH<x>:TRIGger:A:RUNT:WHEn?
Arguments
OCCURS argument specifies a trigger event if a runt of any detectable width occurs.
LESSthan argument sets the oscilloscope to trigger if the a runt pulse is detected
with width less than the time set by the SEARCH:SEARCH<x>:TRIGger:A:
RUNT:WIDth command.
DPO3000 Series Programmer Manual
2-251
Related documents
Programmer Manual
Oscilloscope Programmer`s Reference
Connect-Tek USB-2 Specifications
CH? (Query Only)
Tektronix DPO3034 datasheet: pdf
Programmer Manual TDS 340A, TDS 360 & TDS 380 Digital Real
MEASUrement:MEAS? (Query Only)
DPO3000 Series Digital Phosphor Oscilloscopes User Manual
Tektronix DPO4000 User's Manual
Data Sheet - Thermal Engineering Lab
2012 Bench Products
Instruction Manual / Command Description for the Tracker