UM10198
Philips Semiconductors
Chapter 16: SD card interface
MS_SCLK
MS_BS
3
2
1
cmd state
MS_DAT[0]
0
7
6
5
4
PEND
Z
Z
data counter
3
2
1
CMD
CMD
CMD
SEND
Z
Z
Z
S
CMD
CMD
6
7
CmdPend
Fig 52. Pending command start
The data block counter determines the end of a data block. If the counter is zero, the
end-of-data condition is TRUE (refer to the SD_DataCtrl register description for more
information).
4.4.3 Bus mode
In wide bus mode, all four data signals (MS_DIO[3:0]) are used to transfer data, and the
CRC code is calculated separately for each data bit. While transmitting data blocks to a
card, only MS_DIO[0] is used for the CRC token and busy signalling. The start bit must be
transmitted on all four data signals at the same time (during the same clock period). If the
start bit is not detected on all data signals on the same clock edge while receiving data,
the DPSM sets the start bit error flag and moves to the IDLE state.
The data path also operates in half-duplex mode, where data is either sent to a card or
received from a card. While not being transferred, MS_DIO[3:0] are in the HI-Z state.
Data on these signals is synchronous to the rising edge of the clock period.
4.4.4 CRC token status
The CRC token status follows each write data block, and determines whether a card has
received the data block correctly. When the token has been received, the card asserts a
busy signal by driving MS_DIO[0] LOW. Table 16–266 shows the CRC token status
values.
Table 266. CRC token status
Token
Description
010
Card has received error-free data block.
101
Card has detected a CRC error.
4.4.5 Status flags
Table 16–267 lists the data path status flags (refer to the SD_Status register description
for more information).
UM10198_1
User manual
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
Rev. 01 — 1 June 2006
261 of 396