Download ZigBee OEM Module ProBee
Transcript
ProBee-ZE20S User Guide Rev.1.10.1 7.4.6 AT+STACK or AT+ZS Description Execute Response Get/Set the ZigBee stack profile value. This value must be set the same on all devices that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro) AT+STACK?<CR> <value><CR> OK<CR> Default 0 Range 0-2 7.4.7 AT+STACK=<value><CR> OK<CR> or ERROR<CR> AT+NODENAME or AT+NN Description Execute Response Get/Set the node name. It can be used to make a clear distinction role or functionality of local node from others. AT+NODENAME?<CR> <value><CR> OK<CR> Default ProBee-ZE Range Up to 16 characters 7.5 Network Formation and Join 7.5.1 AT+ASCAN or AT+AS Description Execute AT+NODENAME=<value><CR> OK<CR> or ERROR<CR> Perform a scanning for existing network. It can take up to 5 seconds. (CAUTION: It is possible to cause a link error if a node is a parent of an end-device.) AT+ASCAN<CR> AT+ASCAN=<channel mask><CR> <channel>|<PAN ID>|<EPID>|<joinable>|<stack profile> Response List of the existing networks … OK<CR> 7.5.2 AT+ESCAN or AT+ES Perform a scanning for energy level of all channels. It can be used to avoid Description interference. It can take up to 5 seconds. The RSSI energy level ranges from approximately -100 to +127 in dBm. (CAUTION: It is possible to cause a link error if a node is a parent of an end-device.) Execute AT+ESCAN<CR> <channel>|<RSSI > Response List of the RSSI for each channel … OK<CR> AT+ESCAN=<channel mask><CR> 69