Download Digital pulse width modulation techniques for power

Transcript
At t3, the duty cycle drops from high to low, and the proposed modulator senses the
change and resets the DPWM. It does not wait until the end of switching cycle to reset the
DPWM. Therefore, in the proposed DPWM the turn off delay is reduced. This operation results
in improvement in the output voltage overshoot. Figure 2.3 shows the reduction of turn on delay
caused by the conventional trailing edge digital pulse width modulation.
The operation of MDPWM (to reduce the turn on delay) is as follows. The main
counter is an up counter as it is the case in the trailing-edge DPWM and auxiliary counter is a
down counter. The auxiliary counter starts to count when the DPWM signal is set to low. At t3,
the DPWM signal is low and the auxiliary counter starts to count up until it reaches the duty
cycle. In the conventional modulation scheme the DPWM signal cannot be turned on any time
after the DPWM signal is set to low. It can be turned on only when the main counter finishes
counting. In contrast, the proposed auxiliary counter can turn on any time with reduce turn on
modulation delay. At t1 the duty cycle increases from low to high value and the proposed
modulator senses the change and sets the DPWM. It does not wait until the end of switching
cycle to set the DPWM. Therefore in the proposed DPWM the turn on delay is reduced. This
operation results in improvement in the output voltage undershoot.
25