Download AUDIO PRECISION System One Users
Transcript
34. FURNISHED DISK FILE DESCRIPTIONS Software for non-DSP versions of System One is furnished on four diskettes. DSP versions include additional software on several more diskettes as described in the DSP User’s Manual. The four diskettes furnished with standard System One are the S1.EXE diskette, Tests and Procedures diskette, Utilities & Equalization diskette, and Performance Checks diskette. This chapter lists the files furnished on the first three of these diskettes, along with a brief description of each file. The Performance Check files are not described here since they are all called by performance check procedures, run automatically with the proper limit and sweep files attached, and should not be changed in any way. 34.1. S1.EXE version: 2.10 Diskette 15-GAPSC.TST Test file for Gap Scatter across tracks 10-24 (switcher channels 1-15) of 24-track tape recorder. Measurement plots phase difference at 10 kHz of each track versus track 12 (switcher channel 3), near tape center. 15-TRACK.PRO Procedure to test the frequency response 15-FREQ.TST, distortion versus amplitude 15T-MOL3.TST, worst-case crosstalk versus frequency 15-CRSTK.TST, and gap scatter 15GAPSC.TST of a multi-track tape recorder. Subprocedure for SELECT.PRO procedure. 15T-MOL3.TST Test file for Maximum Output Level (MOL), tracks 10-24 of 24-track recorder operating at 30 inches per second, 0 VU. Nested sweep with amplitude as SOURCE-1, SWR-122 switcher channel as SOURCE-2. S1.EXE System One executable program. @6064.ADF Supplied for the MICRO-CH option only. File used by PS/2 Microchannel Bus reference diskette to configure the computer for System One operation. 34.2. Test and Procedures Diskette 15-CRSTK.TST Test file for worst-case crosstalk versus frequency, tracks 10-24 of 24-track recorder operating at 30 inches per second, 0 VU. Nested sweep with frequency as SOURCE-1, SWR-122 switcher channel as SOURCE-2. 15-FREQ.TST Test file for frequency response, tracks 10-24 of 24-track recorder operating at 30 inches per second, 0 VU. Nested sweep with amplitude as SOURCE-1, SWR-122 switcher channel as SOURCE-2. 22K400BW.TST Test file for frequency response of System One internal 22 kHz high pass and 400 Hz low pass filters. 2HD-FREQ.TST Test file for playback frequency response measurements, using either a tape recorded with 2HD-RCRD.TST or a reference tape. 2HD-PHAS.TST Test file for measuring interchannel phase of two-head tape recorders in playback mode using a pre-recorded tone. 2HD-RCRD.TST Test file to aid in creating a 30 step, frequency response test, for two-head tape recorders. Refer to section 30.2.4.4 for additional information. 2HD-THD.TST Test file for total harmonic distortion versus frequency of two head tape players using a per-recorded tape. 30K100BW.TST Test file for frequency response of System One internal 30 kHz high pass and 100 Hz low pass filters. 34-1