Download AUDIO PRECISION System One Users

Transcript
34. FURNISHED DISK FILE DESCRIPTIONS
Software for non-DSP versions of System One is
furnished on four diskettes. DSP versions include
additional software on several more diskettes as described in the DSP User’s Manual. The four diskettes furnished with standard System One are the
S1.EXE diskette, Tests and Procedures diskette,
Utilities & Equalization diskette, and Performance
Checks diskette. This chapter lists the files furnished on the first three of these diskettes, along
with a brief description of each file. The Performance Check files are not described here since they
are all called by performance check procedures, run
automatically with the proper limit and sweep files
attached, and should not be changed in any way.
34.1. S1.EXE version: 2.10 Diskette
15-GAPSC.TST Test file for Gap Scatter across
tracks 10-24 (switcher channels 1-15) of 24-track
tape recorder. Measurement plots phase difference
at 10 kHz of each track versus track 12 (switcher
channel 3), near tape center.
15-TRACK.PRO Procedure to test the frequency
response 15-FREQ.TST, distortion versus amplitude
15T-MOL3.TST, worst-case crosstalk versus frequency 15-CRSTK.TST, and gap scatter 15GAPSC.TST of a multi-track tape recorder. Subprocedure for SELECT.PRO procedure.
15T-MOL3.TST Test file for Maximum Output
Level (MOL), tracks 10-24 of 24-track recorder operating at 30 inches per second, 0 VU. Nested
sweep with amplitude as SOURCE-1, SWR-122
switcher channel as SOURCE-2.
S1.EXE System One executable program.
@6064.ADF Supplied for the MICRO-CH option
only. File used by PS/2 Microchannel Bus reference
diskette to configure the computer for System One
operation.
34.2. Test and Procedures Diskette
15-CRSTK.TST Test file for worst-case crosstalk
versus frequency, tracks 10-24 of 24-track recorder
operating at 30 inches per second, 0 VU. Nested
sweep with frequency as SOURCE-1, SWR-122
switcher channel as SOURCE-2.
15-FREQ.TST Test file for frequency response,
tracks 10-24 of 24-track recorder operating at 30
inches per second, 0 VU. Nested sweep with amplitude as SOURCE-1, SWR-122 switcher channel as
SOURCE-2.
22K400BW.TST Test file for frequency response
of System One internal 22 kHz high pass and 400
Hz low pass filters.
2HD-FREQ.TST Test file for playback frequency
response measurements, using either a tape recorded
with 2HD-RCRD.TST or a reference tape.
2HD-PHAS.TST Test file for measuring interchannel phase of two-head tape recorders in playback
mode using a pre-recorded tone.
2HD-RCRD.TST Test file to aid in creating a 30
step, frequency response test, for two-head tape recorders. Refer to section 30.2.4.4 for additional information.
2HD-THD.TST Test file for total harmonic distortion versus frequency of two head tape players using
a per-recorded tape.
30K100BW.TST Test file for frequency response
of System One internal 30 kHz high pass and 100
Hz low pass filters.
34-1