Data output format when reading succeeded
When bar code reading is succeeded, following data is transmitted to the upper
equipment.
Header Number
Data of read bar code
Output item
Number of
digit
Footer
Description
Initial setting
Letter strings to add at the head of transmitted data.
Max 4 arbitrary characters can be set.
No header
Number of digit of the read data is output in two-digit ASCII code.
Whether or not to output the number of digit is selectable.
No number of digit
output
Letter strings to add at the end of transmitted data.
Max 4 arbitrary characters can be set.
CR (0DH)
Setting methods of whether to output header, number of digit and footer p.79
Process when reading failed
Output format differs according to what is set to "reading failed process".
Selection of output format when reading failed
No process
Remarks
Nothing is transmitted
BR [CR] is transferred
[STX]?[ETX], [STX]>[ETX] is transferred
?[CR], >[CR] are transferred
–
?:
>:
When it is judged as no bar code
In cases other than above
[CAN] [CR] are transferred
–
[STX] [CAN] [ETX] are transferred
–