Download EMHEATER
Transcript
EM9 User's Manual 6.Detailed Function Description Diagram 6-16 Skip frequency diagram. Code Name Description Setting Range Factory setting 0.0~100.0% (reference 0.0~100.0 0.0% F8.09 Traverse amplitude frequency) F8.10 Jitter frequency 0.0~50.0% (traverse amplitude) 0.0~50.0 0.0% F8.11 Rise time of traverse 0.1~3600.0s 0.1~3600.0 5.0s F8.12 Fall time of traverse 0.1~3600.0s 0.1~3600.0 5.0s Traverse operation is widely used in textile and chemical fiber industry. Traverse operation is the output frequency of inverter traverse to reference frequency as center. The output frequency change track is shown in following diagram. Traverse amplitude set by F8.09. When F8.09 is set to 0, that is traverse amplitude is 0, the traverse operation is disabled. Diagram 6-17 Traverse operation diagram. Center frequency (CF) is reference frequency. Traverse amplitude: The output frequency of traverse is limited by upper frequency limit (F0.05) and lower frequency limit (F0.06). Traverse amplitude relative to center frequency: Traverse amplitude (AW) =center frequency * F8.09. Jitter frequency = traverse amplitude (AW) * F8.10. That is the value of jitter frequency relative to traverse amplitude in traverse operation. Rise time of traverse: Indicates the time rising from the lowest traverse frequency to the highest traverse frequency. Fall time of traverse: Indicates the time falling from the highest traverse frequency to the lowest traverse frequency. 45