Download SETTING INSTRUCTIONS
Transcript
Setting record for thermostat set for six events each day Setting record for thermostat set for two events each day Event Numbers Format 1 2 CLG HTG Event Number 3 CLG HTG CLG 4 HTG 5 CLG HTG CLG 6 HTG CLG HTG Format 1 Pre-set programmes, Monday to Friday 25.0°C 20.0°C 27.2°C 6:30 15.0°C 8:30 25.0°C 20.0°C 27.2°C 11:30 2 CLG 15.0°C 25.0°C 13:30 20.0°C 27.2°C 16:30 CLG Time 15.0°C 22:30 HTG HTG TIme Pre-set programmes, Monday to Friday Actual User Settings, Monday to Friday 25.0°C 1 (Monday) 21.1°C Off 8:30 15.0°C 17:30 Actual User Settings, Monday to Friday 2 (Tuesday) 1 (Monday) 3 (Wednesday) 4 (Thursday) 2 (Tuesday) 5 (Friday) 3 (Wednesday) Pre-set Programmes, Saturday & Sunday 27.2°C 20.0°C 27.2°C 7:30 20.0°C 9:30 25.0°C 20.0°C 25.0°C 11:30 20.0°C 25.0°C 13:30 21.1°C 27.2°C 16:30 15.0°C 22:30 4 (Thursday) Actual User Settings, Saturday & Sunday 5 (Friday) 6 (Saturday) Pre-set Programmes, Saturday & Sunday 7 (Sunday) Off Off 8:30 If the unit is to operate in 5/2 day mode, then only days 1 and 6 need be completed. Off Off 17:30 Actual User Settings, Saturday & Sunday 6 (Saturday) NOTES ON SETTING EVENT TIMES 7 (Sunday) (Assumes unit is in 6 events/day mode) If, during the event checking and setting procedure, no buttons are pressed for more than two minutes then the HP75 will return to RUN mode automatically. If this appears to have occurred, it is advisable to re-check the program to ensure that it is as required. When setting event times and temperatures it is not possible to set event times out of chronological order. Event 1 may be set at any time from 0:00AM to 11:59PM (but would normally be in the morning). Event 2 may be set at any time between event 1 and 23 hours, 59 minutes after event 1. If the event time being set is moved past midnight into the following day then the number of the following day will blink. 15.0°C 00:30 12:30am Event 6 on day 6 set after midnight. EVENT 6 5°C DEAD BAND FACTORY PRE-SET PROGRAMME HEATING 12:00 15:00 EVENTS 2, 3 & 4 18:00 21:00 MIDNIGHT In the diagram opposite, event 2 has been moved to 3:30PM. Note that events 3 & 4 have also been moved to that time and that the following control temperature will be that of event 4. EVENT 6 9:00 EVENT 5 6:00 EVENT 1 3:00 COOLING EXAMPLE USER SET PROGRAMME HEATING MIDNIGHT 2 The factory pre-set programme may be reinstated by pressing the recessed RESET button. This will however reinstate all the factory preset conditions so that the clock type and temperature scale may also have to be re-set. COOLING MIDNIGHT 32°C 31°C 30°C 29°C 28°C 27°C 26°C 25°C 24°C 23°C 22°C 21°C 20°C 19°C 18°C 17°C 16°C 15°C 14°C 13°C EVENT 5 EVENT 1 32°C 31°C 30°C 29°C 28°C 27°C 26°C 25°C 24°C 23°C 22°C 21°C 20°C 19°C 18°C 17°C 16°C 15°C 14°C 13°C EVENT 4 When using the - button to adjust events 2 to 6 and the previous event time is reached the - button ceases to respond. EVENT 3 Event 4 may be set at any time between event 3 and 23 hours, 59 minutes after event 1,.... and so on. EVENT 2 Event 3 may be set at any time between event 2 and 23 hours, 59 minutes after event 1. When using the + button to adjust events 1 to 5 and the event time being adjusted becomes the same as the following event time, then both are changed simultaneously. This applies to all subsequent event times reached and is demonstrated in the diagram on the lower left. 3:00 It is possible to move events past midnight into the following day when the day number will blink in the display, see the display diagram in the notes on setting event times. 3°C DEAD BAND Manual overide used =atUSED 9am MANUAL OVERRIDE AT 9 AM TO RAISE to raise temperature by 2°C. TEMPERATURE BY 2°C. PROGRAMMED 3°C DEAD Programmed 3°C dead band BAND MAINTAINED. maintained. 6:00 9:00 12:00 15:00 18:00 21:00 MIDNIGHT