Download Motion Coordinate System User Manual

Transcript
Appendix
B
Coordinate System Attributes
Use this appendix for information about the attributes used in a coordinate
system.
How to Access Attributes
The Access column shows how you can access the attribute.
Use a Get System Value (GSV) instruction to get the value.
Use a Set System Value (SSV) instruction to set or change the value.
Attribute
Axis Type
Data Type
Access
Actual Position
Tolerance
GSV
SSV
Config Fault
Tag
Coordinate Motion
Status
GSV
Tag
Description
Use the tag for the coordinate system to get the value.
Use the tag for the coordinate system or a GSV instruction to get the value. It’s
easier to use the tag.
Coordinate System Attributes
Attribute
Data Type
Access
Description
Accel Status
BOOL
Tag
Use the Accel Status bit to determine if the coordinated (vectored) motion is currently being commanded to
accelerate.
The acceleration bit is set when a coordinated move is in the accelerating phase due to the current
coordinated move. It is cleared when the coordinated move has been stopped or the coordinated move is in
the decelerating phase.
Actual Pos Tolerance Status
BOOL
Tag
Use the Actual Pos Tolerance Status bit to determine when a coordinate move is within the Actual Position
Tolerance.
The Actual Position Tolerance Status bit is set for AT term type only. The bit is set when interpolation is
complete and the actual distance to programmed endpoint is less than the configured AT value.
The bit remains set after an instruction completes. The bit is reset if either a new instruction is started or the
axis moves such that the actual distance to programmed endpoint is greater than the configured AT value
Actual Position
REAL[8]
Tag
Array of actual position of each axis associated to this motion coordinate system in Coordinate Units.
Rockwell Automation Publication MOTION-UM002D-EN-P - February 2015
255