Download SMT310Q User Manual - Sundance Multiprocessor Technology Ltd.
Transcript
Version 2.1 Page 39 of 55 SMT310Q User Manual Pin No. Signal Pin No. Signal 1 GND 2 DATA0 3 DATA1 4 DATA2 5 DATA3 6 DATA4 7 DATA5 8 DATA6 9 DATA7 10 /CREQ 11 /CACK 12 /CSTRB 13 /CRDY 14 GND Figure 13: FMS connector pin out 12.2.2 Buffered Comport Cabling Connecting between buffered comports requires a 1 to 1 cable; the SMT502Buffer is the recommended cable assembly and can be purchased separately. Cable plugs 3M Scotchflex 10126-6000EL FES part 038740A Plug shells 3M Scotchflex 10326-A200-00 FES part 038760D Cable type 3M Scotchflex KUCKMPVVSB28-13PAIR FES part 038781E This cable has 13 individual pairs, with an overall shield, and an outer diameter of 7mm. Cable length should be as short as possible. The maximum tested cable length is 1 meter. On reset, each comport initialises to being either an input or an output. Do not connect ‘Reset to Input’ comports together. Do not connect ‘Reset to Output’ comports together. However if this should occur, no damage will result, because comport direction signals disable relevant comports.