Download User Manual
Transcript
This User Manual contains information on design, principle of operation, characteristics of the product and instructions essential for correct and safe use of this product (intended use, maintenance, servicing, storage and transportation), as well as information regarding the utilization of the product. 1 DESCRIPTION AND OPERATION OF THE PRODUCT 1.1 Product functionality The alpha-beta radiometer UMF-2000 for low level activity measurements FVKM.412121.001 (hereinafter - radiometer) is intended for measurement of: - total activity of alpha and beta emitting nuclides contained in counting samples of foodstuff, soil and water, collected on air filters and in sorbents, as well as for measuring the activity of nuclides in the samples obtained by selective radiochemical extraction; - total activity of alpha emitting nuclides in “thick” and “thin” counting samples of environmental samples. The radiometer is used in laboratories for monitoring of water bodies. 1.2 Technical characteristics 1.2.1 Energy range of measured alpha radiation ……………….…………… 3500 to 8000 keV. 1.2.2 Energy range of measured beta radiation ………………...……………… 50 to 3500 keV. 1.2.3 Activity measurement range: - alpha radiation ………………….……………………….…….……….….… 0.01 to 103 Bq; - beta radiation …………………...………………….……….………….…… 0.1 to 3·103 Bq. 1.2.4 Limits of the permissible basic relative measurement error ……………………… ±15 %. 1.2.5 Radiometer maintains operability under the influence of the external background gamma radiation with energy of 662 keV and absorbed dose rate 0.50 μGy/h; under these conditions the limit of complementary measurement error is ………………..….………………………..……..…… 15 %. 1.2.6 Background count rate: - detectors with area 450 and 1000 mm2 in the alpha measurement channel ……………….…………..…… not more than 0.001 cps; - detectors with area 450 mm2 in the beta measurement channel ………………….…………..…… not more than 0.03 cps; - detectors with area 1000 mm2 in the beta measurement channel ………………………………...… not more than 0.07 cps. 1.2.7 Contribution of alpha channel into count rate of beta channel for thin alpha source …………………………………………………………..… not more than ±0.8 %. 1.2.8 Warm-up time under stable external conditions, not more than …………...……… 5 min. 1.2.9 Continuous operation during …….….………………….…….….……………… 24 hours. 1.2.10 Instability of readings during 8 hours of continuous operation relative to average value of readings for this period of time ……………………….………………………….…….……… ±5 %. 1.2.11 Power supply of the radiometer is provided from single-phase AC mains with voltage 22 220 33 V, frequency 50 11 Hz. Limits of complementary measurement error due to deviation of voltage or frequency from their values specified for normal operating conditions ……………………………………………±5 %. 1.2.13 Power consumption …………………………..….…….….……… not more than 40 VA. 1.2.14 Operating conditions: - operating temperature range: ……...….….……………….…….....….. minus 10 to + 35C; - maximum limit of relative humidity …………….….……….….…………. 75 % at +30C; - atmospheric pressure ………………………………………………….… 84.0 to 106.7 kPa; - content of the corrosive agents in the ambient air corresponds to the values in Table 1.1. FVKM.412121.001RE 3