1.3.6 The two-channel counting device with timer consists of three counting paths with fourdigit indicators and an electronic timer. The duration of measurement is determined by time selector (four digital switches). Pushbutton switches located on the front panel allow to start the measurement with simultaneous reset of the previous result, and to stop the measurement at any time. 1.3.6.1 The counting scheme is built with the use of a microprocessor; information is displayed on seven-segment LEDs and has two channels. 1.3.6.2 Pulses corresponding to alpha particles are counted in the first channel; the second channel is used for counting of pulses from the beta particles. The indication mode can be changed using buttons “α, β” and “β, TIME”. In the “α, β” mode the indicator displays alpha and beta counts, while in the “β, TIME” mode it is beta counts and elapsed time. The indication mode does not affect the operation of the radiometer. 1.3.6.3 In the case of an overflow in one of the channels counting stops and the central segments are lit at the indicator corresponding to the overflowed channel. At that it is possible to view the content of other channels. Stopping of counting is accompanied by an audible signal. To turn the signal off press the “STOP” button or start a new measurement. 1.4 Marking and sealing 1.4.1 The following information is presented on the radiometer: - trademark and name of the manufacturer (supplier); - reference designation of the radiometer; - works number of a radiometer according to the manufacturer's system of numeration; - degree of ingress protection against solid items and water provided by casings; - voltage, power consumption or current, power supply frequency. 1.4.2 Location and method of marking of the radiometer correspond to the design documentation. 1.4.3 The radiometer is sealed in accordance with the design documentation. 1.5 Packing 1.5.1 The radiometer’s package complies with the design documentation and provides protection against ingress of atmospheric precipitations and aerosols, splashes of water, dust, sand, solar ultra-violet radiation and limits the ingress of water vapour and gases. 2 INTENDED USE 2.1 Operational limitations 2.1.1 Radiometer retains operability under conditions stated in 1.2. 2.1.2 Using mobile phones is prohibits near the operating radiometer. WARNING! DO NOT USE RADIOMETER FOR PERFORMING MEASUREMENTS OF SAMPLES WITH HIGH CONTENT OF ACIDS OR ALKALI TO PREVENT DAMAGE TO THE WORKING SURFACE OF DETECTOR. 2.2 Preparation of the product for use 2.2.1 Before using the radiometer check that the power cord is connected correctly and not damaged, check grounding. After that connect the power cord to the wall outlet and turn the power switch located on the rear panel to the “POWER ON” position. At that time the red LED must light up located next to the marking “POWER” on the front panel. FVKM.412121.001RE 6