Download 1 Press
Transcript
5 Advanced Operations Multi-SP Selected set point 4 SP 4 5 SP 5 6 SP 6 7 SP 7 Note: The set point can also be switched using communications. 5-4-3 Operation Commands Other than Multi-SP The following table shows the functions that can be assigned when an Event Input Assignment 1 or 6 parameter is displayed. *1 *2 *3 *4 Setting Function none None stop RUN/STOP manu Auto/Manual prst Program Start*1 drs Invert Direct/Reverse Operation rsp SP mode switch*2 at-2 100% AT Execute/Cancel at-1 40% AT Execute/Cancel*3 wtpt Setting Change Enable/Disable cmwt Communications Write Enable/Disable*4 lat Alarm Latch Cancel msp0 Multi-SP No. switching bit 0 msp1 Multi-SP No. switching bit 1 msp2 Multi-SP No. switching bit 2 PRST (Program Start) can be set even when the Program Pattern parameter is set to OFF, but the function will be disabled. This function can be set only for a Controller that supports a remote SP input. This function can be set for heating/cooling control, but the function will be disabled. This function can be set only for a Controller that supports communications. Also, when a work bit is selected as the event input data, Communications Write Enable/Disable cannot be assigned. Turn event inputs ON and OFF while the power is being supplied. Event input ON/OFF changes are detected for inputs of 50 ms or longer. The functions are described in detail below. z Executing Run/Stop Control When the Event Input Assignment parameter is set to STOP (RUN/STOP), control is started when event input turns OFF. Control is stopped when the input turns ON. Alarm outputs, however, will be according to the process value. The STOP indicator will light while control is stopped. Setting Event input Event input Input contact ON OFF Status STOP RUN z Switching between Auto and Manual Control When the Event Input Assignment parameter is set to MANU (auto/manual), manual control will start when event input turns ON. Auto control will start when the input turns OFF. The MANU indicator will light during manual control. 5 - 12 E5CC/E5EC Digital Temperature Controllers User’s Manual (H174)