Transcript
Report No.: Page 16 of 65 11010447 001 IEC 60950-1 / EN 60950-1 Clause Requirement – Test 2.10.8 Spacings filled by insulating compound................: Certified sources of optical isolators used. No other components applied for. (see appended table 2.10.5). P Electric strength test See above. 2.10.9 Component external terminations See appended table 1.5.1, 2.10.3 and 2.10.4. P 2.10.10 Insulation with varying dimensions No reduction of distance applied. 3 WIRING, CONNECTIONS AND SUPPLY P 3.1 General P 3.1.1 Current rating and overcurrent protection All internal wires are UL recognized wiring, which is PVC insulated, rated VW-1, min. 80°C. Internal wiring gauge is suitable for current intended to be carried. P 3.1.2 Protection against mechanical damage Wires do not touch sharp edges and heatsinks, which could damage the insulation. P 3.1.3 Securing of internal wiring Internal wires are secured by solder, cable tie or other mechenical connect so that a loosening of the terminal connection is unlikely. P 3.1.4 Insulation of conductors The insulation of the individual conductors is suitable for the application and the working voltage. For the insulation material see 3.1.1. P 3.1.5 Beads and ceramic insulators Not used. 3.1.6 Screws for electrical contact pressure Electrical and earthing connections screwed two or more complete threads into metal. No screws of insulating material for electrical and earthing connections. P 3.1.7 Insulating materials in electrical connections To ensure proper earth connection through the PCB, screws and spring-washers are provided to compensate possible shrinkage of the PCB material. P 3.1.8 Self-tapping and spaced thread screws No self-tapping or spaced thread screws used. TRF No.:IECEN60950_1B Result – Remark Verdict N/A N/A N/A TRF originator: SGS Fimko