Download Untitled

Transcript
Report No.:
Page 8 of 65
11010447 001
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
1.7.6
Fuse identification (marking, special fusing
Fuse marking label adjacent to
characteristics, cross-reference) ............................: the fuse holder on PCB:
Verdict
P
F801 T3.15AH 250V
CAUTION: FOR CONTINUED
PROTECTION AGAINST A RISK OF
FIRE REPLACE ONLY TYPE WITH
SAME TYPE AND RATINGS OF FUSE.
1.7.7
Wiring terminals
1.7.7.1
Protective earthing and bonding terminals ..........: Appliance inlet is provided. The
symbol of 60417-1-IEC-5019
was located on PCB.
1.7.7.2
Terminal for a.c. mains supply conductors
The equipment is provided with
appliance inlet, which is for
connection of a detachable type
power supply cord.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
No such conductors.
N/A
1.7.8
Controls and indicators
See below.
1.7.8.1
Identification, location and marking .....................: The marking and indication of
the stand-by switch is located
that indication of function is
clearly.
P
1.7.8.2
Colours ...............................................................: The colours of the Power LED
indicator are as follows:
- Blue for ON condition
- Amber for power saving mode
P
1.7.8.3
Symbols according to IEC 60417 .........................: Marking according 60417-1IEC- 5009 (line half inside
circle) provided above the
stand-by switch.
P
1.7.8.4
Markings using figures ........................................: No indicators for different
positions of control.
N/A
1.7.9
Isolation of multiple power sources .....................: Single power source only.
N/A
1.7.10
IT power distribution systems
For Norway compliance has to
be evaluated during the
national approved.
N/A
1.7.11
Thermostats and other regulating devices
Neither thermostats nor other
regulating devices provided.
N/A
1.7.12
Language(s) .........................................................: User’s manual provided in
English and German. Marking
label provided in English.
Versions in other languages will
be provided during national
approval.
TRF No.:IECEN60950_1B
P
See below.
P
P

TRF originator: SGS Fimko