RS 232 Connection
RS 232
SYSTEM A
1830
ELEVATOR
1
Voice/Data cellular system
should be as close as
possible to SYSTEM A.
2
3
MIC
VOL
3 2 1
3 2 1
SPK
VOL
FEED
BACK
Auxiliary
Terminal
3 2 1
1800-010
1816
1816
Voice/Data Cellular System
HF
GREEN - Good Signal
YELLOW - Poor Signal
RED - No Signal
Power
Icon
POWER
Board
Power
LED
Cellular Module
NO
RJ45
Cable
PROGRAM
NORMAL
RS 232
“A” LEDs
Master
Code
Button
RS 232
PH LINE
PH LINE
DATA OUT
DATA IN
BUSY OUT
BUSY IN
GROUND
RS 232
“B”
SYSTEM B
RESET
The EARTH GROUND must be connected to a proper
ground close by (ground rod, cold water pipe in the
ground, existing electrical ground, etc.).
Installation
16.5VAC
20 VA
16.5VAC
40 VA
ONLY
RS 232
1
2
3
4
5
6
1830
Terminal
1
2
3
4
5
RS 232
SYSTEM B
Optional 1830
ELEVATOR
1
2
FEED
BACK
1816
3 2 1
1816
1NC 1NO BAT 16AC 16AC
The cellular system can also be powered directly from the
transformer if desired.
Twisted Pair Phone
Line MUST be used.
t
ke
rac
g B are
n
i
t
un rdw
Mo d Ha
an
1C
Power Supply - Supplied power transformer can be used
to power cellular system AND Aux terminal of a DoorKing
phone entry system. If Aux terminal is already being
powered by a 16.5 VAC, 20 VA transformer, replace it with
the 16.5 VAC, 40 VA transformer that is supplied to power
both devices.
RS 232 Connection
System B
Terminal
DATA OUT
DATA IN
BUSY OUT
BUSY IN
GROUND
2RY
Existing
Power
Twisted Pair Phone Line
MUST be used.
DATA OUT
DATA IN
BUSY OUT
BUSY IN
GROUND
RS 232
“A”
2C
Voice
Earth
Ground
Data
RS 232
“B” LEDs
A
PH LINE
PH LINE
RS 232
Ethernet
Data/Link
D
LINK
LEDs DATA
Z
1&2
Program
Slide
Switch
NC
18 AWG Min. Power Wire
POWER
SOURCE
SYSTEM A
ON/OFF
Button
CGND PSW MIC COM SPKR IMD 5VDC IMC
16VAC
16VAC
E GND
Power
MASTER
CODE
MASTER
CODE
RING
Main Terminal
Network Name: DOORKING- XXXX
Password: XXXXXXXX
Ethernet
ON
PHONE
SIM ID: XXXXX
Jumper
MUST be
Moved
5&6
OFF
KEYPAD
3 2 1
Signal
Strength
Bars
Data
HS
6 7 8 9 10 11 12 13 14
hosted by AT&T cellular network
with DKS Online Registration Completed
1
2
3
4
5
6
Jumper
MUST be
Moved
3
SPK
VOL
TWO Entry Systems - The Voice/Data
cellular system can supply telephone
service and programming for TWO 1830s
designated as System A and System B.
The telephone line is SHARED with both
1830s. Each 1830 MUST be programmed
for Multiple Systems, see specific 1830
Installation/Owner’s instruction manual
for more information.
3
6 7 8 9 10 11 12 13 14
DKS Cellular Server
RS 232
1830
Terminal
1
2
3
4
5
1 2 3 4 5
System A
Terminal
DATA OUT
DATA IN
BUSY OUT
BUSY IN
GROUND
1 2 3 4 5
Wiring
HF
HS
ON
MASTER
CODE
OFF
KEYPAD
NO
NC
RING
PHONE
The plastic enclosure
comes with mounting
re
brackets and hardware to mount
Wi
on enclosure. Mount enclosure on
n
u
R
surface using appropriate hardware (not
re
Wi
included). IT IS NOT RECOMMENDED DRILLING
HOLES IN THE PLASTIC ENCLOSURE!
If holes must be drilled, remove the circuit board before drilling and be sure that
mounting bolts/screws do not touch the back of the circuit board. Holes must be
sealed to prevent water intrusion.
CGND PSW MIC COM SPKR IMD 5VDC IMC
Z
A
2C
2RY
1C
1NC 1NO BAT 16AC 16AC
n
Ru
1800 065-C-7-15
Voice
16.5VAC
20 VA
16.5VAC
20 VA
Existing Power
2