Download Manual - Encon Electronics
Transcript
RS 232 Connection RS 232 SYSTEM A 1830 ELEVATOR 1 Voice/Data cellular system should be as close as possible to SYSTEM A. 2 3 MIC VOL 3 2 1 3 2 1 SPK VOL FEED BACK Auxiliary Terminal 3 2 1 1800-010 1816 1816 Voice/Data Cellular System HF GREEN - Good Signal YELLOW - Poor Signal RED - No Signal Power Icon POWER Board Power LED Cellular Module NO RJ45 Cable PROGRAM NORMAL RS 232 “A” LEDs Master Code Button RS 232 PH LINE PH LINE DATA OUT DATA IN BUSY OUT BUSY IN GROUND RS 232 “B” SYSTEM B RESET The EARTH GROUND must be connected to a proper ground close by (ground rod, cold water pipe in the ground, existing electrical ground, etc.). Installation 16.5VAC 20 VA 16.5VAC 40 VA ONLY RS 232 1 2 3 4 5 6 1830 Terminal 1 2 3 4 5 RS 232 SYSTEM B Optional 1830 ELEVATOR 1 2 FEED BACK 1816 3 2 1 1816 1NC 1NO BAT 16AC 16AC The cellular system can also be powered directly from the transformer if desired. Twisted Pair Phone Line MUST be used. t ke rac g B are n i t un rdw Mo d Ha an 1C Power Supply - Supplied power transformer can be used to power cellular system AND Aux terminal of a DoorKing phone entry system. If Aux terminal is already being powered by a 16.5 VAC, 20 VA transformer, replace it with the 16.5 VAC, 40 VA transformer that is supplied to power both devices. RS 232 Connection System B Terminal DATA OUT DATA IN BUSY OUT BUSY IN GROUND 2RY Existing Power Twisted Pair Phone Line MUST be used. DATA OUT DATA IN BUSY OUT BUSY IN GROUND RS 232 “A” 2C Voice Earth Ground Data RS 232 “B” LEDs A PH LINE PH LINE RS 232 Ethernet Data/Link D LINK LEDs DATA Z 1&2 Program Slide Switch NC 18 AWG Min. Power Wire POWER SOURCE SYSTEM A ON/OFF Button CGND PSW MIC COM SPKR IMD 5VDC IMC 16VAC 16VAC E GND Power MASTER CODE MASTER CODE RING Main Terminal Network Name: DOORKING- XXXX Password: XXXXXXXX Ethernet ON PHONE SIM ID: XXXXX Jumper MUST be Moved 5&6 OFF KEYPAD 3 2 1 Signal Strength Bars Data HS 6 7 8 9 10 11 12 13 14 hosted by AT&T cellular network with DKS Online Registration Completed 1 2 3 4 5 6 Jumper MUST be Moved 3 SPK VOL TWO Entry Systems - The Voice/Data cellular system can supply telephone service and programming for TWO 1830s designated as System A and System B. The telephone line is SHARED with both 1830s. Each 1830 MUST be programmed for Multiple Systems, see specific 1830 Installation/Owner’s instruction manual for more information. 3 6 7 8 9 10 11 12 13 14 DKS Cellular Server RS 232 1830 Terminal 1 2 3 4 5 1 2 3 4 5 System A Terminal DATA OUT DATA IN BUSY OUT BUSY IN GROUND 1 2 3 4 5 Wiring HF HS ON MASTER CODE OFF KEYPAD NO NC RING PHONE The plastic enclosure comes with mounting re brackets and hardware to mount Wi on enclosure. Mount enclosure on n u R surface using appropriate hardware (not re Wi included). IT IS NOT RECOMMENDED DRILLING HOLES IN THE PLASTIC ENCLOSURE! If holes must be drilled, remove the circuit board before drilling and be sure that mounting bolts/screws do not touch the back of the circuit board. Holes must be sealed to prevent water intrusion. CGND PSW MIC COM SPKR IMD 5VDC IMC Z A 2C 2RY 1C 1NC 1NO BAT 16AC 16AC n Ru 1800 065-C-7-15 Voice 16.5VAC 20 VA 16.5VAC 20 VA Existing Power 2