System structure with 1 CLC controller 12-3
SYNAX
Deactivated drive
A deactivated drive is not switched into operating mode. It remains in
phase 0...2.
Plug-in module in deactivated
drives
The CLC does not address deactivated drives. This means that functions
that access a plug-in card in a deactivated drive will not operate properly.
Examples:
• binary I/Os (DEA)
• analogue inputs (DAE)
• real master axis (e.g. DFF).
Note:
The binary outputs of a deactivated drive (e.g., "drive ready to
operate", _A:F#.02) are not emulated.
Checking the drive configuration
When running up the system, the CLC checks drive projection. The
addresses of the drives within the ring are read in and compared with the
entries on the list of "addresses projected drives" (C-0-0002) and
"addresses deactivated drives" (C-0-0086). If there is a contradiction
between the parametrized projection and the physical ring configuration,
then it will not be possible to run up the system. The CLC will issue an
error message.
The results of the drive check are stored in two parameters:
• The addresses of the recognized drives are entered in the list
"addresses recognized drives" (C-0-0087).
• The addresses of those drives that can actively participate in
operations, are stored in the list "addresses operatable drives"
(C-0-0088).
12.3 Parameters
The following is a list of the systems parameters relevant to the SYNAX
ring. For details see "SYNAX Parameter Description".
Parameter
number
Designation
C-0-0002
Addresses projected drives
C-0-0007
Fiber optic cable (LWL) length
C-0-0086
Addresses deactivated drives
C-0-0087
Addresses recognized drives
C-0-0088
Addresses operatable drives
A-0-0006
Drive deactivation
Fig. 12-2: System parameters in the SYNAX ring
DOK-SYNAX*-SY*-06VRS**-FK01-EN-P