Transcript
Order data/reference lists 6-5
Rexroth SYNAX 200
Brief description DAQ04
The DAQ card is an ARCNET slave interface and a PPC link interface.
The PPC link can be built as a single ring or a double ring.
Mixed operation with the DAQ03 is not possible.
General specifications DAQ04
ARCNET interface
coaxial connector, 92 Ohm
ARCNET transmission rate
2.5 Mbit/s
ARCNET max. number of participants
255 participants (via
deviation/repeater)
PPC link
fibre-optics cable interface according
SERCOS interface
Max. number of link participants
64
Fig. 6-10: General specifications DAQ04
Interface LAG (hardware option G2)
YG000076V01_NN.bmp
Fig. 6-11: Interface LAG G2
Brief description LAG
The LAG card is a master encoder interface to connect master encoders
to the PPC.
Up to two EnDat master encoders can be connected.
General specifications LAG
Encoder interface
Sub-D strip 15-way
Encoder types
EnDat
Power supply encoder
24V via 2-way Phoenix connector
Max. connectable encoders
2
Fig. 6-12: General specifications LAG G2