Control Computer Messages
Report Error 8211
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
** 8211<B> MODADDR=<addr>
REPORT ERROR: Automatic switchover failed; standby switch failure.
Rec act: Replace active switch. Reboot node.
Message Explanation
An automatic switchover to the standby Switch module failed because the Control Computer
could not get an echo from the standby Switch module.
Recommended Action
Physically remove the standby Switch module from its slot and reinsert it.
Enter restore switch to restore the standby Switch module.
If the problem persists, replace and restore the Switch module.
The Node Reference provides information for these procedures.
Report Error 8212
*
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
8212<B> MODADDR=<addr> PORT=<num> MODTYPE=<modtype>
REPORT ERROR: Bad Format: Frame has non-integral number of octets
Rec act: Check access line
Message Explanation
The FRM or FRM-M2 received a frame that did not end on an 8-bit boundary. A noisy facility
between the module and the access device could cause this problem.
Recommended Action
Enter dmeas <mod type> and check the output of the BAD FRAMES field to determine the
number of bad frames that have been detected on the line. The number that appears in this
field is in direct proportion to the severity of the problem (the higher the number, the more
critical the problem).
Follow instructions in the Frame Relay Module Reference or the Data Networking Products
M2 Frame Relay Module Reference dmeas <mod type> report field description for BAD
FRAMES to determine the cause of the problem.
Replace hardware as needed. The Installation chapter of the Frame Relay Module Reference
or Data Networking Products M2 Frame Relay Module Reference provides information for
this procedure.
If transmission errors are apparent, contact your facilities provider for service.