Download DNP Messages Reference

Transcript
________________
Control Computer Messages
Report Alarm 7040
*
<YY-MM-DD> <hh:mm:ss> NODE=<xxx...x>
7040<B> SHELF=<num>
REPORT ALARM: Shelf power over-consumed
Rec act: Check all shelf modules
Message Explanation
The power consumption on the indicated shelf is greater than the shelf capacity. This can cause
loss of data and/or services to the modules on the shelf.
Recommended Action
Enter verify shelf to determine the total current allowed for the shelf and the configuration of
modules on the shelf.
Redistribute the modules across Series M2 shelves.
Reconfigure the modules in the database.
The Administration chapters in the Node Reference and in the appropriate module references
provide information for these procedures.
2-86
Data Networking Products Messages Reference, Issue 5