4W315C
Dayton Operating Instructions and Parts Manual
Dayton Diesel Electric Generator
®
Specifications
ELECTRICAL SPECIFICATIONS
Rated
Wattage*
Maximum
VA
Rated Amperage
120V
Rated Amperage
240V
5000
6500
41.7
20.8
* Single-phase, 1.0 power factor
NOTE: Ratings apply to SAE standard conditions. Reduce ratings 3 1/2% for each 1000 feet above sea level and 1% for each 10°
Fahrenheit rise above 60°F.
GENERAL SPECIFICATIONS
Yanmar
Engine H.P.
Yanmar
Model
Fuel
Type
Fuel Tank
Capacity
Oil Alert
System
Electric
Start
Weight
(pounds)
10
L100
Diesel
4.2 gal.
Yes
Yes
241
RECEPTACLE SPECIFICATIONS
120V
Duplex
Yes
120V, 30-Amp
Twist-Lock
Yes
120/240V, 20-Amp
Twist-Lock
Yes
120V Full
Power Switch
Yes
ELECTRICAL COMPONENT SPECIFICATIONS
Stator
Main
Winding *
Resistance in Ohms
Stator
Rotor
Auxiliary
Primary
Winding ∆
Winding †
Rotor
Secondary
Winding †
Capacitor,
MFD
450 Volt
Diodes (2)
800 Volt
0.54
1.38
2.29
50
70 Amp
0.61
(*) Connect T2 (green) and T3 (black). Measure resistance between T1 (red) and T4 (yellow).
(∆) Resistance between brown and white leads.
(†) Remove diodes to check resistance.
107358