Transcript
See “Tunable Expressions” in the Real-Time Workshop User’s Guide for a detailed description of the use of tunable parameters in expressions. S-Function Target Enhancements S-function target enhancements include: • The S-function target now supports variable-step solvers. • The S-function target now supports tunable parameters. • The new Generate S-function feature lets you automatically generate an S-function from a subsystem. The S-function target is now documented the Real-Time Workshop User’s Guide. See the chapter “The S-Function Target” for a full description of S-function target features. External Mode Enhancements Several new features have been added to external mode: • The default operation of the External Signal & Triggering dialog box has been changed to make monitoring the target program simpler. See “External Signal & Triggering Dialog Box” in the Real-Time Workshop User’s Guide for details. • Signal Viewing Subsystems have been implemented to let you encapsulate processing and viewing of signals received from the target system. Signal Viewing Subsystems run only on the host, generating no code in the target system. This is useful in situations where you want to process or condition signals before viewing or logging them, but you do not want to perform these tasks on the target system. See “Signal Viewing Subsystems” in the Real-Time Workshop User’s Guide for details. • Previously, only Scope blocks could be used in external mode to receive and view signals uploaded from the target program. The following now support external mode: - Dials & Gauges Blockset - Display blocks - To Workspace blocks - Signal Viewing Subsystems 3-5