Download ESS M-BLASTER Specifications

Transcript
PRELIMINARY
ES1879 DATA SHEET
REGISTERS
Spatializer Audio Processor Registers
Spatializer Auto-Limit Scale Factor 2
This section describes registers related to the Spatializer
3-D audio processor.
Spatializer Enable and Mode Control
0
0
0
0
7
6
5
4
(50h, R/W)
Spatializer enable Reset Mono mode Auto-limit
3
2
1
0
Reset to zero by hardware reset.
3
1 Mono
mode
1 = Mono-in, stereo-out mode.
0 = Stereo-in, stereo-out mode.
Spatializer Level/Limit
6
0
1
2
1
0
This register, along with mixer register 54h, is used to set
scale factors used by the automatic limit mechanism.
Program this register to 95h (149 decimal) as shown.
Recommended values are subject to change in the future.
3
2
1
Bit Definitions:
Bits Name
Description
7:6 0
Reserved. Always write 0.
2
1
0
Description
7:4 Autolimit
increase
rate
Specifies the rate at which gain can be
increased, relative to the decrease rate:
Max_Increase_Rate =
Max_Decrease_Rate/(N+1); N is bits 7:4 of this
register.
3:0 Autolimit
decrease
rate
Specifies the rate at which gain can be
decreased:
Max_Decrease_Rate = 1378 Hz / (N+1)
N is bits 3:0 of this register.
Auto-limit low-level effect boost
7
6
(54h, R/W)
1
0
0
0
1
1
1
1
7
6
5
4
3
2
1
0
This register, along with mixer register 56h, is used to set
scale factors used by the automatic limit mechanism.
Program this register to 8Fh (143 decimal) as shown.
Recommended values are subject to change in the future.
5
4
Threshold
Auto-limit energy threshold
enable
3
2
1
0
Reset to zero by hardware reset.
Bit Definitions:
Bits Name
Spatializer Auto-Limit Scale Factor 1
SAM0025A-062397
3
Spatializer Auto-Limit Threshold and Offset(5Ah,R/W)
5:0 Spatializer 0 is minimum effect; 3Fh is maximum effect. If
level/
the auto-limit function is enabled (mixer regislimit
ter 50h bit 0), then this register specifies the
maximum effect level (actual effect determined
by automatic level setting mechanism). If the
auto-limit function is disabled, then this register
sets the current effect level.
70
4
Bits Name
0
Reset to zero by hardware reset.
Reset to zero by hardware reset.
5
Bit Definitions:
(52h, R/W)
4
6
(58h, R/W)
Auto-limit decrease rate
Reset to zero by hardware reset.
Spatializer level/limit
5
1
3
The recommended value for this register is 94h:
0 Auto-limit 1 = Enable automatic effect limiter.
0 = Disable automatic effect limiter.
7
0
4
Max_Decrease_Rate = 276 Hz
Max_Increase_Rate = 2480 Hz
1 = Release from reset.
0 = Reset Spatializer.
0
1
5
7
1 = Enable Spatializer effect.
0 = Disable Spatializer effect (effect unit
bypassed).
2 Reset
0
0
6
Auto-limit increase rate
Reserved. Always write 0.
Spatializer
enable
0
7
Spatializer Auto-Limit Mode Rate
Description
7:4 0
1
Reset to zero by hardware reset.
Bit Definitions:
Bits Name
(56h, R/W)
Description
7:4 Auto-limit Increases Spatialization effect for low-level
low-level
signals.
effect boost
3 Threshold
enable
2:0 Auto-limit
energy
threshold
1 = Enable auto-limit energy threshold
requirement.
0 = Disable auto-limit energy threshold
requirement.
1 = Enable minimum energy level setting of
input signal to make auto-limit decisions.
0 = Disable minimum energy level setting of
input signal.
ESS Technology, Inc.