INTRODUCTION
The Linea 7 range is comprised of 3 models of combination boiler – 726, 730, 735 – with outputs to heating &
DHW of 26, 30 & 35 kW respectively. Each appliance –
by design – incorporates electronic ignition, circulating
pump, expansion vessel, safety valve, pressure gauge,
and automatic by-pass.
The Linea 7 range are produced as room sealed, category II2H3+ appliances, suitable for internal wall mounting applications only. They are provided with a fan powered flue outlet with an annular co-axial combustion air
1
intake that can be rotated – horizontally – through 360
degrees for various horizontal or vertical applications. The
Linea 7 range can also be used with the Vokera twin flue
system.
The Linea 7 range is approved for use with C12, C22, &
C32 type flue applications.
These appliances are designed for use with a sealed
system only; consequently they are not intended for use
on open vented systems.
2
Fig.1 General Layout
24
3
4
5
23
6
22
7
21
8
20
9
19
10
11
18
12
17
13
16
14
15
25 26 27 28 29
32
31
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Flue Outlet
Air Intake
Differential analog Pressure Switch
Silicone Pressure Tube
Silicone Negative Pressure Tube
Expansion Vessel
Main Heat Exchanger
Electrode
Burner Temperature control
Transformer
Gas Valve
Modulator Coil
Domestic Heat Exchanger
Domestic Hot Water Flow Switch
Safety Valve
Pressure Switch
Diverter Valve Motor
Pump
Automatic Air Release Valve
Main Burner
Combustion Chamber
Fan Assembly
Air Chamber (with front removed)
Flue Gas Analysis Test Point
Hot Water Temperature Control
Mode Selector Switch
Status LED
Temperature Indicator
Central Heating Temperature Control
Combustion Switch
Timeclock Aperture (optional)
Pressure Gauge
30
Fig. 1
Linea
1