Download 1 Contents
Transcript
2 Introduction Thank you for purchasing the AOR AR7030 high dynamic range, short wave, all mode receiver. The AR7030 is designed using the very latest DDS (Direct Digital Synthesis) technology to ensure the highest levels of performance and reliability. A TCXO (Temperature Compensated Crystal Oscillator) is provided for high stability. To get the best possible results from your AR7030 we recommended that you carefully read this manual and familiarise yourself with the receiver. Many apparent faults are often due to accidental mis-operation of the receiver so, if you think there is a problem, carefully read all of the manual before deciding to return the receiver for repair. Every effort has been made to make this manual correct and up to date. Due to continuous development of the receiver and by error or omission anomalies may be found and this is acknowledged. © This manual is protected by copyright AOR Manufacturing Ltd 1995, 1996. No information contained in this manual may be copied or transferred by any means without the prior written consent of AOR Ltd. AOR and the logo are trade marks of AOR Ltd. All other trade marks and names acknowledged. E&OE 2-1 Accessories supplied Mains power supply Infrared remote controller and batteries Operating manual 2-2 Overview - read THIS if nothing else The AR7030 receiver pushes forward the frontiers of performance and microprocessor operation. In order to get the very best out of the receiver you will need to carefully read through all the sections of this handbook, however there are a few points worth noting first:a. The receiver has been designed to be compact and robust enough for transportable operation, and as such there are relatively few front panel controls. The infrared remote controller should be considered as an extension of the front panel, offering single button access to many primary functions. The receiver can be operated without the infrared controller but more button presses may be required to perform the same operation. The infrared control input is accepted by sensors on both the front and rear panels of the receiver. If you cannot reliably enter commands with the controller in close proximity to the front panel, move it to one side of the receiver and make sure that an object behind the receiver will provide a reflection into the rear sensor. The infrared controller is powered by two AAA size 1.5V batteries (supplied) which have to be fitted before it can be used... observe the polarity carefully. You cannot harm the receiver by pressing buttons, turning knobs or exploring the menu options - experiment without worry. Only by using the receiver will you become fully conversant with its operation. PAGE 2 AR7030 OPERATING MANUAL If you really mess up the settings, a LOAD DEFAULT facility has been included so that you can return the set to its out-of-box condition (except for frequency memory contents). Loading the defaults will ensure:- sensible filters are selected for each mode of reception, no PBS offset, no BFO offset for CW and DATA modes, maximum IF gain with AGC on, auto synchronous AM, auto RF attenuation, flat tone control settings, standard line output levels etc. To load the default settings, press (to return to the SETUP menu), rotate the spin-wheel one click anticlockwise so that the legend Deflt Set is displayed, and then press the button. Loaded .. is briefly displayed in place of the clock to confirm selection. Should the filters appear incorrectly aligned or nonsymmetrical, please refer to FILTER CALIBRATION in section 6-2 and look through section 6-1. b. The receiver does not have a standard format of display readout - it can be configured to display time or pass band shift or filter selection or treble / bass tone selection or VFO selection or AGC or memory configuration... whatever YOU choose. The spin-wheel and the button will retain their last assigned functions when the button is pressed allowing a selected function to be changed whilst the S-meter is displayed. To return to the SETUP menu and CLOCK display, press . To display the S-meter and return to the root level of the menu system, press . You may tune the receiver, change the volume and reception mode or select fast tune whilst any menu is shown on the display because these front panel controls have only one dedicated function. These are fixed controls, and are indicated in this manual with white lettering on a black background, similar to the lettering on the front panel. Similarly the and buttons always have a defined function. The other receiver controls, arranged beneath the display, are referred to as SOFT-KEYS, because their function varies according to the context of the selected menus. In these cases the control description is displayed on the receiver’s LCD and in this manual with black lettering on a grey background. When no menu is displayed on the LCD - when the S-meter is shown - then the underlying buttons select the menu indicated on the panel:- MEMORY, RF / IF or FILTER. c. Each mode can have, and will retain, a different filter bandwidth (chosen from those available), pass band shift (PBS) setting, BFO setting and AGC speed. When adjusting any of these settings the values are changed only for the current mode selected. Squelch value for NFM mode is held separately from the value for all other modes.