Download Comtech EF Data UT-4518E Product specifications
Transcript
Errata A Comtech EF Data Documentation Update Subject: Revised 5.6.4.7 Packed Configuration Status Date: Document: December 16, 2005 UT-4500 Series, Up Converters, Installation and Operation Manual, Revision 1, dated June 20, 2005 MN/UT4500.EA1 Attach this page to page 73 Part Number: Collating Instructions: Comments: Revise paragraph 5.6.4.7 to read: Change Specifics: 5.6.4.7 Packed Configuration Status Configuration Status: <DEV/PACRCS_'cr' Confirmation: >DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf'] where: aaaa = # of 125kHz steps above base frequency1 bbb = # of 0.25 dB steps above 0.00 dB2 c = 1 if Transmitter ON, 0 if OFF, 2 if Cold d = 1 if unit ONLINE, 0 if OFFLINE e = 1 if Redundancy ON, else 0 ff = converter # (01-12,BU or 00 if e = 0) gg = 00 if 'ff' is 00 (redundancy OFF) gg = chain length (01-12) if 'ff' is BU gg = XX if 'ff' = 01 - 12 h = A if Auto Mode, M if Manual3 I = 1 if Cold Start Enabled, else 0 j = 1 if Auto recovery enabled, else 0 K = 1 if an Ext. Ref is present, else 0 l = 1 if Remote Mode, 0 if Local Mode Notes: Filename: T_ERRATA 1 If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the base frequency. Also, this will be 5 bytes(aaaaa) long for model 4513X converters with 125 KHz frequency step size. This will be 7 bytes(aaaaaaa) long for all 1KHz step size converters. 2 If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above the base frequency 3 If it is a backup Converter, it is always ‘A’. 4 If it is the primary converter, gg = P1 or P2 (single or dual polarity system. 1