Download Clear-Com ECLIPSE MATRIX Instruction manual
Transcript
4 MAINTENANCE TROUBLESHOOTING TIPS Listed below are some of the more common problems the panel may experience, their possible causes, and suggested solutions. Symptom System does not operate and the talk light does not turn on when talk button is pressed. • Sometimes when the talk light doesn’t work it’s because the panel isn’t receiving power. • When the system doesn’t operate, make sure there isn’t an incompatibility problem. Vitec Group Communications ICS-22 Speaker Panel Instruction Manual System does not operate and the call waiting light blinks slowly. Cause 1. The panel is not receiving 14- to 16-VAC power. Solution 1. Check the circuit powering the panel and make sure all plug connections are secure. 2. The panel has an has an internal failure. 2. The panel requires servicing. Communication with Make sure each the system is lost. eight-wire, modular connector is securely plugged in, check the wiring, and ensure that the Matrix system is turned on. An incompatibility Contact the dealer or problem with the Clear-Com’s technical Matrix system. service. System does not operate and the call waiting light blinks quickly. Speaker does not 1. The speaker knob is operate, but the talk turned all the way light comes on when down. talk button is pressed. 2. The speaker plug or wiring has come loose. Hum or buzz in Inductive pickup system. caused by close proximity of this speaker panel or connected panels to power lines or transformers. 1. Adjust control appropriately. 2. Make sure speaker is connected internally. Relocate the offending unit or wiring. 4-1