Download Alarko HARMONY - D Technical data
Transcript
38 ATTENTION! Step 3 of Fig.17 shows how to fit the terminal duct from inside the room where access to the outside wall is not possible. Such a sliding operating can be done providing that the optional wall liner is used. (This is required to seal any cavity and to allow the sealing ring to pass through from inside and provide an adequate external seal). The wall liner is a tube of 130 mm diameter with a wall thickness of 0.8 mm. This step may be skipped where outside wall is accessible and the terminal duct can be pushed through the wall from outside. In this case, an adequate smaller hole can be drilled on the wall to be able to pass the Ø100 mm terminal duct. 4.2.6 Installing the Flue System with Straight Extension Kit: In case the total length required for a straight outlet from the wall is more than 725 mm, 500 and/or 1000mm extension kits should be used with the standard kit. Refer to Fig. 18.